7.1.4 The outdoor fan control (exchange fan)
When the fan is changed among every airflow speed (including stop blowing), in order to avoid
the airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds.
Antifreezing protection of the indoor heat exchanger
When refrigerating/heating, prevent freezing.
Tpg_indoor
is the minimum value of the effective indoor unit (start it and it is in accord with the
running state).
When Tpg_indoor
ice_temp_1 , the frequency of the compressor decreases at the speed of
1HZ/1second.
When Tpg_indoor
ice_temp_2 , the frequency of the compressor decreases at the speed of
1HZ/10seconds.
When Tpg_indoor begins to rise again, and ice_temp_2 =Tpg_indoor = ice_temp_3 , the
frequency of thecompressor doesn’t change.
When ice_temp_3 Tpg_indoor ice3 , the frequency of the compressor increases at
the speed of 1HZ/10seconds.
For example, Tpg_indoor<= 0
last for 2 minutes, and then the outdoor unit will stop, and report
underload malfunction, but don’t send malfunction report to the indoor.
The compressor stops for more than 3 minutes, Tpg_indoor> ice2 , the compressor
recovers.
Temperature protection of the outdoor refrigerating coil
When the defrosting temperature and the sensor’s temperature are higher than 64 , the
frequency of the compressor decreases 1hz/10seconds.
When the temperatures are lower than 64
and higher than 60 , keep
the frequency of the compressor. When the temperatures are higher than 70 , relieve the
defrosting temperature protection.
11 //ice5
9
y
l
w
o
l
s
g
n
i
s
a
e
r
c
n
I
3
+
3
_
p
m
e
t
_
e
c
8 //ice2
Keeping the frequency
ice_temp_3
7
6
ice_temp_2
3
Decreasing slowly
ice_temp_1
3
Decreasing rapidly
ice_temp_1
1
Stop
7.1.3.5
7.1.3.6
Functions and control
Domestic air conditioner
20
Summary of Contents for 2U40S2SM1FA
Page 11: ...Pinping diagrams Domes t ic air condit ioner 4 Pinping diagrams 9 ...
Page 12: ...Operation range Domestic air conditioner 5 Operation range 10 10 0 21 27 35 20 40 60 43 20 40 ...
Page 15: ...wiring diagram Domestic air conditioner PCB 1 13 NOTE J3 OFF STATUS ...
Page 16: ...wiring diagram 14 Domestic air conditioner PCB 2 ...
Page 33: ...Dimensional drawing 31 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity ...
Page 63: ...Domestic air conditioner Sincere Forever ...
Page 64: ...Wall Mounted Type DC Inverter FREE MATCH N Series 2U40S2SM1FA Model No ...