Refrigeration/dehumidification mode::
Serial No.
Temperature scope
Frequency limitation
1
Wh_c<16
Max_hz1 45 HZ
2
Wh_c<23
Max_hz2 52 HZ
3
Wh_c<29
Max_hz3 60 HZ
4
Wh_c<32
Max_hz4 67 HZ
5
Wh_c<40
Max_hz5 75 HZ
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system.
When the starting ability is not the maximum, its maximum frequency limitation is calculated by
the following equations:
Refrigeration/dehumidification:
Heating mode
< 0
< 2
< 3
< 4
≥ 4
The percentage of
the rated frequency P
80%
90%
95 %
100%
110%
< 0
< 2
< 3
< 4
≥ 4
The percentage of the
rated frequency P
80%
90%
98%
105 %
115%
The indoor set
airflow speed
Breeze Low Medium High
Strong Quiet Healthy
airflow
Ki
60
70% 85%
100% 108%
60%
60%
Functions and control
Domestic air conditioner
17
6
Wh_c<48
Max_hz4 71 HZ
7
Wh_c>48
Max_hz5 60 HZ
<1
85%
<1
85%
F
(
reference frequency
)
=∑Fi
(
reference frequency
)
Note - valid internal machine (starting and running in accordance with the state) to participate
in the calculation
Fi
(
reference frequency
)=
Fei
(
Computed base frequency
)
*Kw
(
Outer ring temperature coefficient
(
External ring temperature on frequency limitation
section
))
*Pi
(
Temperature difference between the weight
)
*Ki
(
Wind speed weight
)
(
Note: the reference frequency Fi is rounded after calculation and no rounding is performed
;)
i= machine A, machine B...
Pi
Pi
Summary of Contents for 2U40S2SM1FA
Page 11: ...Pinping diagrams Domes t ic air condit ioner 4 Pinping diagrams 9 ...
Page 12: ...Operation range Domestic air conditioner 5 Operation range 10 10 0 21 27 35 20 40 60 43 20 40 ...
Page 15: ...wiring diagram Domestic air conditioner PCB 1 13 NOTE J3 OFF STATUS ...
Page 16: ...wiring diagram 14 Domestic air conditioner PCB 2 ...
Page 33: ...Dimensional drawing 31 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity ...
Page 63: ...Domestic air conditioner Sincere Forever ...
Page 64: ...Wall Mounted Type DC Inverter FREE MATCH N Series 2U40S2SM1FA Model No ...