WaterMax 60 Series Owner’s Manual
4/29/2008
17
Service Settings, Cont.
Display
Meaning
Possible Values
Comments
72–96 Hour
Regeneration
No
A way to force regeneration at
regularly-scheduled intervals
No (or Yes, for iron)
See 72–96 Hour
Regeneration that follows.
Displays only when in
Modes 2 or 3
Distiller/RO
No
Indicates if a distiller or reverse
osmosis appliance is plumbed to use
filtered water from the appliance
No (or Yes if a distiller or
reverse osmosis appliance
is used)
Displays only when in
Mode 2
Backwash 1
01.0
Number of minutes the first backwash
cycle lasts
00.0 to 99.9
Set to the nearest tenth of
a minute
Brine/Rinse 30.0
Number of minutes the first brine and
slow rinse cycle lasts
00.0 to 99.9
Set to the nearest tenth of
a minute
Backwash 2
05.0
Number of minutes the second
backwash cycle lasts
00.0 to 99.9
Set to the nearest tenth of
a minute
Salt per
Regen lbs.
06.2
Amount of salt set to be used in each
regeneration to achieve the capacity
setting
00.0 to 99.9 lb (kg)
Set to the nearest tenth
Turbine Pulses
Normal
Used by qualified personnel for
diagnostic purposes
Normal
Test Mode
Regenerate
Tonight
Yes
Sets the appliance to regenerate
tonight
No or Yes
If set to Yes, it will force a
regeneration at the next
set regeneration time
(such as 02:00 AM). After
the regeneration, the value
will be set to No.
Displays only when in
Modes 1 or 2