WaterMax 60 Series Owner’s Manual
4/29/2008
16
Service Settings, Cont.
Display
Meaning
Possible Values
Comments
Total
Regens
00000
Total number of regenerations since
Service Settings was last entered
Cannot be reset
00000–99999
Total
Gallons
00000000
Total amount of water that has
passed through the appliance since
Service Settings was last entered
Cannot be reset
00000000–99999999
Mode 1
Frequency
Operating (Regeneration) Mode
Mode 1
Frequency
Mode 1
Days of the Week
Mode 2
Demand Delayed
Mode 3
Demand
See Operating Modes
section that follows
Days
Between Regenerations
01
Number of days between
regenerations
00 to 12
Displays only when in
Mode 1
Frequency
Regen
Days
SMTWTFS
YYYYYYYY
Select which days to regenerate
Various combinations or Y’s
and blank spaces
Displays only when in
Mode 1
Days of the Week
Hardness
Grains
040
Hardness of the water that was
tested
003 to 999 Grains
(00000 to 99999 mg/L)
This is the actual hardness
reading and is not
compensated for iron
Iron
ppm
00
Amount of iron in parts per million of
the water that was tested
00 to 99 ppm (mg/L)
This value is used to
calculate compensated
hardness automatically
Manganese
ppm
00
Amount of manganese in parts per
million of incoming water
00 to 99 ppm (mg/L)
This value is used to
calculate compensated
hardness automatically
Salt Type
Sodium
Regenerant filling the brine tank
Sodium
Potassium
Compensated
Hardness
00040
Compensated hardness using the
hardness, iron, and manganese
settings
Cannot be set
ppm or (mg/L)
The formula used is:
Ha (4 x each ppm
iron) + (4 x each ppm
manganese) =
compensated hardness
Capacity
Grains
28730
The desired capacity number
00000 to 99999 Grains
(0000 to 9999 gm)