Service Settings
To program Service settings on the controller, press and hold the Select and Display buttons while “Service
Settings” is displayed until “Set Language Eng” is displayed. Programming Service Settings is similar to
programming Customer Settings (see
Customer Settings
for programming details). The values that can be set
are listed below. The values in the table are factory default settings only.
Note:
The Service Settings must be set before the Customer Settings.
Display
Meaning
Possible Values
Comments
Set Language Eng
Set the language of the
display
Set Language Eng
Entrer Langue Fra
Entre La Leng. Esp
Units ENG
Units of measure
ENG or MET
Soft. v. # 1.22B
Displays the current
software version
Cannot be set
Mode
2 Operating
Mode:
Timer (Mode 1)
Meter Delayed (Mode 2)
1 or 2
See
Operating Modes
Regen Freq.
01
How often regeneration
occurs
1–12 days
Mode 1
Hard. Gr.
040
Hardness of the water that
was tested
003 to 999 Grains
(00000 to 99999 mg/L)
This is the actual hardness reading
and is not compensated for iron
Iron ppm
00
Amount of iron in parts per
million of the water that
was tested
00 to 99 ppm (mg/L)
This value is used to calculate
compensated hardness automatically
Mang. ppm
00
Amount of manganese in
parts per million of
incoming water
00 to 99 ppm (mg/L)
This value is used to calculate
compensated hardness automatically
Salt =
Sodium Regenerant filling the brine
cabinet
Sodium or Potassium
See
Warning
Comp. Hard.
00040 Compensated hardness
using the hardness, iron,
and manganese settings
Cannot be set
ppm or mg/L
The formula used is:
Ha (4 x each ppm iron) +
(4 x each ppm manganese) =
compensated hardness
Capac. Gr.
28730 The desired softening
capacity number
00000 to 99999 Grains
(0000 to 9999 gm)
See
Water Conditioner Specifications
or
Modes 1 and 2 Setting Chart
for
capacities based on salt usage
72–96 hr Regen No
A way to force
regeneration at regularly-
scheduled intervals
No (or Yes, for iron)
See
72–96 Hour Regeneration
Backwash 1
01.0
Number of minutes the first
backwash cycle lasts
00.0 to 99.9
Set to the nearest tenth of a minute
Warning:
When iron and/or manganese is present in the water supply, do not use potassium chloride as a
regenerant. Iron and/or manganese bacteria may develop and foul the conditioning media and may
void the warranty.