INSTALLATION
Pre-Installation
Checklist
Be sure to check the following items before installing a Series 96:
Water Pressure
—
Not less than 20 psi (138 kPa) nor greater than 120 psi
(828 kPa).
Minimum Flow Rate Required
—
2.4 gpm at the end of drain line.
Drain
—
Drain the appliance to a floor drain or washer drain. To prevent
back siphoning, the installer must provide an adequate air gap or a siphon
break.
Water Quality
—If water supply contains sulfur, bacteria, iron bacteria,
tannins, algae, oil, acid, salt, or other unusual substances, special equipment
must be installed ahead of the Series 96.
Building Codes
—
All installations must conform to local plumbing and
electrical codes.
Minimum Inlet Pipe Size
—
Well water recommended minimum inlet pipe
size 3/4" I.D. (19 mm). Municipal water recommended minimum inlet pipe
size is 1/2" I.D. (12.7 mm).
Installation Cautions
Do not install if the above items are not satisfactory.
Do not install if incoming or outlet piping water temperature exceeds
120°F (49°C).
Do not allow soldering torch heat to be transferred to valve components or
plastic parts.
Do not use for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
•
•
•
•
•
•
•
•
•
Series 96 Owner’s Manual
5
NOTE: If your water pressure is greater
than 90 psi (621 kPa), it is
recommended that you use a pressure
reducing valve.