background image

Setting The 4 Button Controller

13

DEMAND REGENERATION

You won't have to worry about vacation settings or extra guests because the controller measures
water usage and regenerates based on need. The appliance will regenerate using only the neces-
sary amount of water and salt. If power has been turned off, your appliance will retain programmed
settings indefinitely. See figure 9.

1)  ENTERING YOUR HARDNESS SETTING 
See page 12 for determining your setting number. Push the “SET” button for about 5 seconds.
Now, the water hardness setting number shown in the digital readout will increase 1 grain each time
you push the "CHANGE" button. After 70 grains for 

Model 700MM 

the read-out will return to 03,

and continue to count up until the display number matches the hardness number. Press the “SET”
button to save the hardness number. To recheck the hardness, hold down the "SET" for about 5 sec-
onds.

2) GALLONS REMAINING
After setting water hardness, gallons remaining until the next automatic regeneration is shown in the
digital display. NOTE: Gallons remaining are in hundreds. 12=1,200 gallons

3) RECHARGE/REGENERATION STATUS
Regeneration cycle numbers are shown during regeneration. The read-out will flash with the cycle
number. The flashing regeneration numbers are:

First cycle:

(01) First Backwash

Second  & Third cycles:

(02) Brine/Slow Rinse 

Fourth cycle:

(03) Second Backwash

Fifth cycle:

(04) Brine Refill

Sixth cycle:

(HO) Service

To quickly advance through the regeneration cycles, press and hold the Regenerate button for 2
seconds. Wait for the cycle to begin, after 20 seconds press and hold the Regenerate button until
the cycle number changes (about 2 seconds.) Each cycle can be advanced in this manner.

4)  waterMizer
The waterMizer

®

wheel will turn whenever water is being used. See figure 9.

5)  REGENERATE
To start an immediate regeneration, press The “Regenerate” button and hold for 3 seconds. The
Regenerate button is used when starting your water conditioner, to start an immediate regeneration,
or to restore capacity if you have run out of salt. If your appliance has run out of salt, you may not
have soft water available. Open the salt lid and add salt. Wait two hours, then press the 
"REGENERATE" button and hold for 3 seconds. See figure 9.

6)  POWERCLEAN

The powerClean™ feature is a service/maintenance step for water supplies that have an excessive
amount of iron. Activating this feature is a simple push of the powerClean™ button on the controller.
PowerClean™ will appear in the display when this feature is activated. The appliance will regener-
ate every other day with five pounds of salt. Leave the powerClean™ feature on for a minimum of
two weeks. The frequent regeneration will elimate iron buildup in the resin bed. The use of salt with
an iron cleaning agent or iron out cleaner is recommended for continuous use as a preventive
measure against iron fouling of the resin bed. To deactivate this feature, simply press the
powerClean™ button. Use this feature every six months as a part of your routine maintenance pro-
cedure to insure a long service life for your water treatment appliance. See figure 9.

Summary of Contents for 700MM

Page 1: ...INSTALLATION AND SERVICE MANUAL 4343 S Hamilton Road Groveport Ohio 43125 Version 1 Model 700MM Water Softener...

Page 2: ...FORE INSTALLATION 3 DO S AND DON TS 4 REFERENCE ILLUSTRATIONS 5 CYCLES 10 INSTALLATION AND START UP PROCEDURES 11 SETTING THE 4 BUTTON CONTROLLER 13 CARE MAINTENANCE AND PARTS 16 SPECIFICATIONS CAPACI...

Page 3: ...allation __________________________________ Model Number _____________________________________ Serial Number ______________________________________ Returned Limited warranty Card Date ________________...

Page 4: ...Do not use Potassium Chloride if there is iron in your water 3 Should your electricity be turned off for any reason you must reset the time of day if you programmed your appliance for delayed regener...

Page 5: ...figure 1 5 Electricity The transformer supplied is a standard 120 volt 60 cycle A C for USA or 220 volt 50 cycle A C for outside the USA See figure 8 6 Water Quality If the water supply contains sulfu...

Page 6: ...ms are not satisfactory 2 Do not install if incoming or outlet piping water temperature exceeds 120 degrees Fahrenheit Please see specification on page 25 3 Do not allow soldering torch heat to be tra...

Page 7: ...commended when installing your appliance A bypass appliance also provides access to untreated water when required i e for lawn and gardening purposes Also see figures 4 through 6 Caution If less than...

Page 8: ...e and fills the small void areas that may exist between the threads When the joint is complete there will be a small bead of sealant at the fitting interface indicating a properly joined connection 2...

Page 9: ...ve Part 93884 may be available through your local hardware store plumber or call our HelpLine 1 800 437 8993 From 8 am to 5 pm EST to order Note Do not plumb bypass valve in backward Male pipe threads...

Page 10: ...Figure 8 8 Reference Illustrations PLUGGING IN TRANSFORMER Do not plug transformer into an outlet that is controlled by on off switch Figure 7 OVERFLOW CONNECTION 1 2 I D...

Page 11: ...9 Reference Illustrations Figure 10 ADDING SALT TO THE BRINE CABINET 2 GALLONS WATER Figure 9...

Page 12: ...drawn out of the brine cabinet and up through the media tank cleaning the resin bed and releasing accumulated hardness and iron 3 Slow rinse A slow up flow rinse process then flushes out the brine har...

Page 13: ...ase drain line to 5 8 I D Also the end of the drain line must be equal in height or lower than the control valve See figure 1 3 Flushing Before placing your appliance in service it is very important t...

Page 14: ...nstead of using test strips contact the company below to test for hardness iron and pH WATERSCREEN National Testing Laboratories Inc 1 800 458 3330 9 am 5 pm EST If you feel you have an abnormal amoun...

Page 15: ...generation cycles press and hold the Regenerate button for 2 seconds Wait for the cycle to begin after 20 seconds press and hold the Regenerate button until the cycle number changes about 2 seconds Ea...

Page 16: ...a specific time e g at 2 am when less water is being used Demand Mode triggers a regeneration as soon as softening capacity is exhausted Pressing and releasing the SET button will advance programming...

Page 17: ...l display Pressing and releasing the SET button will save the regen time displayed and put the unit into operation Default is 2 AM PROGRAMMING IS NOW COMPLETE 4 Button Error Descriptions E1 Home magne...

Page 18: ...CRIPTION QUANTITY 1 54306 Salt Port Lid 1 2 54324 Valve Cover Assembly 1 3 54540 700 Computer Control Assembly 1 4 93245 12V Transformer Power Cord 1 5 54303 Cabinet 1 6 54305 Support Panel 1 7 93530...

Page 19: ...inet Overflow 1 2 54510 I O Adapte Assembly 1 3 93838 O Ring 2 4 93808 O Ring 2 5 54520 Drive End Cap c 1 6 93870 Screw 4 7 90828 O Ring 1 8 93501 Injector Assembly 1 9 93835 Sleeve 2 10 90614 2 4 Dra...

Page 20: ...tor Assembly PART DESCRIPTION QUANTITY 1 93810 Injector Screen 1 2 93223 Injector Throat 1 3 93220 Injector Seal 1 4 93221 Injector Nozzle 1 5 93232 Top Injector Seal Thin 1 6 93222 Injector Cap 1 7 9...

Page 21: ...sembly 19 PART DESCRIPTION QUANTITY 1 54313 3 4 IO Adapter 1 2 90232 Turbine Sensor Cap 1 3 90809 Sensor Cap Screw 1 4 93858 Turbine Sensor Assembly 1 5 90522 Turbine Assembly 1 6 93229 Flow Director...

Page 22: ...4 93238 Drive Gear 1 5 90809 Screw Cam Cover 2 6 93219 Piston Slide Cam Cover 1 7 93217 Piston Slide Cam 1 8 93583 Drive End Cap 1 9 93216 Piston Slide 1 10 90818 Screw 2 11 54521 Brine Valve Assembl...

Page 23: ...PART DESCRIPTION QUANTITY 1 93620 Piston Assembly 1 includes O ring Spring 2 90821 O ring 1 3 93260 Housing 1 4 90843 5 pm Flow Control 1 5 93805 O ring 1 6 54314 BrineValve Cap 1 7 90807 Screw 2 8 54...

Page 24: ...Care Maintenance and Parts Figure 17 Safety Shutoff Assembly 22 PART DESCRIPTION QUANTITY 1 54226 Safety Shutoff 1 2 54227 Float 1 3 54228 Air Check 1...

Page 25: ...23 Care Maintenance and Parts Figure 18 Brine Valve Elbow Assembly PART DESCRIPTION QUANTITY 1 54112 1 2 Compression Assembly 1 2 54138 3 8 Compression Assembly 1 3 201120 3 8 Nylon Insert 1 2 1 3...

Page 26: ...Care Maintenance and Parts Figure 19 Bottom Fill Plug Assembly 24 PART DESCRIPTION QUANTITY 1 90238 Fill Plug 1 2 90819 O ring 2...

Page 27: ...uired gpm Maximum Chlorine ppm Controller type Regeneration time minutes HC High Capacity Regeneration time minutes HE High Efficiency Water used regeneration gallons HC High Capacity Water used regen...

Page 28: ...sing Test by placing magnet on the sensor chip If indicator turns clean or replace tur bine If no lindicator replace sensor Repair the leak Plug in transformer Check power source Make sure outlet is n...

Page 29: ...l relative to salt setting Check lines for loose connections Verify adequate pressure and volume of water supply See specifications page 25 Defective circuit board fig 9 Computer control not attached...

Page 30: ...he appliance is represented as being capable of handling these substances in the product specifications other special treatment of the water supply must be used to remove these substances before they...