Clogged line strainer screen
Air leak in suction flow to pump
Restricted solution flow to pump
Suction hose collapsed
Faulty hydraulic pump
Faulty hydraulic motor on
solution pump
Internal restriction of diaphragm
such as build up of chemical
Blown fuse
Faulty ground
Dirty contact terminals
Separation in wire
Faulty switch
Short in solenoid coil
Bad valve
Solution pump not producing
normal pressure
Malfunction of electric solution
valve
R e m o v e s c r e e n ; c l e a n
thoroughly; tighten strainer cap
to avoid air leak
Inspect and tighten all fittings on
suction line
Main solution tank shut-off valve
or valves not completely open
Obstruction at inlet end of hose,
causing high vacuum on hose
Replace hydraulic pump
Replace motor
Disassemble; inspect; clean;
reassemble
Replace fuse
Clean and tighten ground
Clean contact terminals
Check continuity and replace
wire
Replace switch
Replace valve
Replace valve
NOTE:
If your unit is equipped with a high-pressure system, call
the Hagie Manufacturing Customer Support Department
for possible causes and suggested remedies.
SUGGESTED REMEDY
PROBLEM POSSIBLE
CAUSE
107
X.
TROUBLE SHOOTING
Summary of Contents for DTS 8 HI-TRACTOR