52/64
CMp
| Installation
Bosch Rexroth AB, RE 15409 Version 08.2022,
42608
7.3.2.1 Hydraulic motor (SLSP 21, 22,23)
7.3.2.2
Pump
(SLSP 21, 22,23)
Fig. 57:
Recommended mounting position on Hägglunds motor
Fig. 58:
Recommended mounting position in Hägglunds Drive Unit
It's important that the sensor is mounted with correct length of straight pipe
before and after the sensor.
Note!
Placement of the sensor should be done inside the drive unit to keep it
protected from the environment. Here, the existing hose used between the pump
and drain filter can be used to connect the pump and sensor, but an additional
hose must be added between the sensor and the drain filter. Depending of where
sensor is placed, you might need two new hoses.
It's important that the sensor is mounted with correct length of straight pipe
before and after the sensor.
Note!
The sensor should be placed where it is
protected from falling material and is not disturbing daily work. Be sure to always
use a hose from motor to sensor as
.
42610