15.2.3. Socket
This section concerns the current status of the sockets.
T2S mode 3 socket:
2TE mode 2 socket:
Field
Possible value
Note
Slider =
Immediate; Delayed; Pin (Test mode)
Immediate; Delayed; Pin (Test mode)
Current_selector =
13 A; 16 A; 20 A; 25 A; 32 A
Charging current set
Tariff =
Low tariff; High tariff
Off-peak tariff; Peak tariff
CHP_Input =
Open; Close
External signal status (Open; Closed)
Temp =
[0-125]°C
Temperature of the B1280 controller board
Key_Switch =
Locked; Unlocked
Charging station locked/Charging station
unlocked
Installation_phases =
Single-phase; Three-phase
Single-phase; Three-phase
[Socket1]
BP_Timer
0 s
EVSE_Contactor
Open
EV_consumption_p1 =
0 A
EV_consumption_p2 =
0 A
EV_consumption_p3 =
0 A
HMI_status
Ready
Charging_Mode
3
Cable
32 A
Ctrl_pilot
Typical
State
A1
[Socket2]
BP_Timer
0 s
EVSE_Contactor
Closed
EV_consumption_p1 =
0 A
HMI_status
Ready
Charging_Mode
2
Cable
Connected
Field
Possible value
Note
BP_Timer
0-60 Seconds
Time remaining to change the D/N mode with the BP
EVSE_Contactor
Open; Close
Contactor Open; Closed
EV_consumption
nA
n: Instantaneous charging station current
HMI_status
"
Off
Ready
Ready tic faulty
Ready tic idle
Ready (Purple)
Waiting for EV reaction
Waiting for EV (de)connection
Waiting for authorization signal ie:
\ D/N; CHP; TIC;
Blackout resume timer
Waiting for authorization signal ie:
\ D/N; CHP; TIC;
Blackout resume timer; M3 release
Waiting for Power availability or M3 release
Waiting for Power availability / Wifi start
Waiting for Power request from EV
EV Charging (led cycle ~10s)
EV Charging (led cycle ~20s)
EV Charging with faulty TIC
EV Charging with standby TIC
EV Charging after Load Shedding
EV don’t request charging
EV don’t request charging (tic faulty)
EV don’t request charging (tic standby)
Fatal Error
Error"
"This corresponds to the LED statuses. Each of these could be
followed by the Access Point (AP) on the B1280 controller.
Off
Ready
Ready tic faulty
Ready tic idle
Ready (Purple)
Waiting for EV reaction
Waiting for EV (de)connection
Waiting for authorisation signal, i.e.
D/N; CHP; TIC;
blackout timer in case of power failure
Waiting for authorisation signal, i.e.:
D/N; CHP; TIC;
blackout timer; M3 version
Waiting for power supply or M3 version
Waiting for power availability/Wi-Fi start-up
(depending on charging station version)
Waiting for Power request from EV
Vehicle charging in progress (LED cycle approx. 10s)
EV Charging (led cycle approx. 20s)
EV Charging with faulty TIC
EV Charging with standby TIC
EV Charging after Load Shedding
EV don’t request charging
EV don’t request charging (tic faulty)
EV don’t request charging (tic standby)
Fatal Error
Error”
Charging_Mode
2;3
Charging mode 2 or 3
Cable
Failed; 13 A; 20 A; 32 A; 63 A; Not Connected; Un-
known
"Cable value: Failed; 13 A; 20 A; 32 A; 63 A; Not Connected;
Unknown
Failure means that the cable resistance coding is outside of
tolerance"
Ctrl_pilot
Standard; Simplified -> Current Max 10 A
Standard; Simplified -> Current Max 10 A
State
A1; A2; B1; B2; C1; C2; D1; D2; E; F; U:
as defined in the standard IEC 61851-1
A1; A2; B1; B2; C1; C2; D1; D2; E; F; U:
as defined in the standard IEC 61851-1