LED status display
The LED status display (1) is switched off during normal operations. Press the operation but-
ton (2) at the bottom of the LED status display to turn it on and display the current status of the
energy storage system for approximately 1 minute (Table 3).
(1)
(2)
Figure 5: LED status display and operation button
(1) LED status display
(2) Operation button
If the LED status display moves up, the energy storage system id charging. The top LED of the
LED status display indicates the charging level (20%, 40%, 60%, 80% or 100%). If the LED
status display moves down, the energy storage system is discharging. The top LED of the LED
status display indicates the current charge (20%, 40%, 60%, 80% or 100%).
► For detail see
Energy storage system operating instructions
LED status display
Charging / discharging
status
Green light
increasing to 60%
System charges to 60%
Green light
decreasing from 100%
System discharges from
100%
Green light
constant display
(e.g. 40%)
No activity, charge approx.
40%
flow
Energy storage system