Warning  :

This device is to be installed only by a 
professional electrician fitter according to
local applicable installation standards. 

Test and validation of detection
zone

Set potentiometer 

2

to Test mode. 

The Test mode is available for 3 minutes time
and does not take brightness level into
account. 
Each detected movement turns LED 

A

on for 2

seconds. 
The associated receiver is not under control.
After 3 minutes without detection, the product
is set back to auto mode. 
Limitation of detection zone :
You can limit the detection zone using the
shutters supplied or by inclining the head. 

Mounting

Projection or ceiling mount :
- Fix the wall plate using the supplied screws. 
- Clip the detector onto the wall plate
- Tighten the screws to close. 

For angle mounting, the wall fixing plate is 
fitted between the accessory and
the detector.

Precautions for installation

For optimum detection conditions, please
follow these recommendations :
- Keep the detector protected from solar

radiation and bad weather, as it is sensitive
to these conditions. 

- Maintain 1m distance between the light

source and the detector and keep the
detector out of the light source.

Product Description and working
principles

This detector allows remote control of one 
or more receivers for a given time when a
movement is detected in its detection zone. 
This product can be used in two types of
configuration: one detector controls
one/several receiver(s); several transmitters
control the receiver(s). 

Operation

The receiver(s) is(are) under control as soon as
the brightness level as set by potentiometer

2

is considered too low and a movement is

detected. 
Upon detection, the time delay is restarted. 

If LED 

A

flashes quickly during configuration,

the position of potentiometer 

1

is not compa-

tible with the selected function.

If LED 

B

flashes quickly or nothing occurs

when starting configuration, check that the
batteries are correctly installed and replace
them if necessary. Product factory reset is
recommended before any new configuration.

Factory return

Keep push-button 

J

depressed until LED

cfg

(flashes (>10s), and then release it.

LED 

cfg 

is turned off when factory return is

completed.
This operation causes full delete of product
configuration in any configuration mode. 
After factory return, wait 15s before starting. 

Action

Adjustments 

Potentiometer 

Use Auto (factory)
settings to set 
automatic lighting
turn-on for 
a given time. 
Only available when
a detector’s time
delay is set. 

Auto Settings

Put the Lux potentiometer on

auto test

”.

The settings are predefined :
Lux = 

(operating at night only)
time = 3 min,
sensitivity = max

auto

lux

test

Turn automatic 
lighting on for 
a given time.
Only available when
a detector’s time
delay is set.

Installer settings

15 min

30 s

5 min

auto

-

+

lux

test

Test and confirm
detection zone. 

Test mode

Move the potentiometer 

to “

auto test

”. 

auto

lux

test

auto

lux

test

Adjust sensitivity.

Allows setting the range
to avoid disturbance.

-

+

Hereby, hager Controls, declares that this motion detector
output is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.

The CE declaration can be consulted on the site :

www.hagergroup.net

Usable in all Europe

and in Switzerland

Installing batteries

Button

cfg

cfg

LED C

Button 

J

Configuration (button 

J

)

These detectors can be configured in 3 different
ways :
• 

: tool-free configuration (using product

pushbuttons and LEDs), see User's Instructions
6T7952 supplied with the product. 

• TX100/B V2.5.0 or above : 

description of product functions available from
the Manufacturer.

• ETS3 or via TR131 : database and description of

application software available from the
Manufacturer.

Configuration by TX100 or ETS

Set the product in configuration mode by pressing

J

button once during the teaching session of

TX100 or for addressing with TR131 in ETS.

O

Product factory return is required to change
the configuration mode. 

quick

link

Summary of Contents for tre50 series

Page 1: ...0 White TRE521 Anthracite 15 min s 5 min auto lux test 30 α IP55 90 30 80 Description Detection zone Installation Wall fixing plate Adjustment potentiometers Directional detection head Adjustments Shutters Angle fixing support Vertical adjustment Optimal installation height is 2 5m The detection zone shall remain free of obstacle 8 m 16 m 2 5 m 0 5 m 16 m 4 m LED A LED B Delay lighting time Bright...

Page 2: ...n starting configuration check that the batteries are correctly installed and replace them if necessary Product factory reset is recommended before any new configuration Factory return Keep push button J depressed until LED cfg flashes 10s and then release it LED cfg is turned off when factory return is completed This operation causes full delete of product configuration in any configuration mode ...

Page 3: ...tions 2 Set the potentiometer to position 3 Configure the timer function See the Configuration Instructions on each receiver for each transmitter involved Note During configuration of a detector Step 2 of the Configuration Instructions shall be ignored TROUBLESHOOTING PROBLEM CAUSES SOLUTIONS Unwanted lamp switch on Permanent heat source is active in the detection area trees bushes shook by wind o...

Page 4: ... TRE501 Antrasiitti TRE520 Valkoinen TRE521 Antrasiitti 15 min s 5 min auto lux test 30 α IP55 90 30 80 Kuvaus Tunnistusalue Asennus Asennuslevy seinäkiinnitykseen Säätöpotentiometrit Suunnattava tunnistuspää Asettelu Maskit Lisätarvikkeet kulma asennukseen Pystysuunnan säätö Optimaalinen asennuskorkeus on 2 5 m Tunnistusalueen tulee olla esteetön 8 m 16 m 2 5 m 0 5 m 16 m 4 m LED A LED B Kiinteä ...

Page 5: ...ot on asennettu oikein ja vaihda ne tarvittaessa Palautus tehdasasetuksiin suositellaan tehtäväksi ennen uuden opetuksen tekoa Palautus tehdasasetuksiin Pidä painike J painettuna kunnes LED cfg vilkkuu 10s ja vapauta sen jälkeen LED cfg sammutetaan kun palautus tehdasasetuksiin on tehty Tämä toiminto poistaa kaikki eri ohjelmointitilojen asettelut tuotteelta Tehdasasetusten palautuksen jälkeen odo...

Page 6: ...pötila 20 C 60 C IK 04 Tiiveysluokka IP55 Tulen kesto 750 C Standardit EN 60950 1 EN 301489 3 EN 300220 2 EN 50491 3 Tunnistimen viiveen asettelu Vastaanottimen viiveen asettelu 15 min 30 s 5 min 15 min s 5 min 30 Pakkaus TRE700 720 Esi aseteltu PÄÄLLE POIS kytkentätoiminto 1 Poista aikaisempi esiaseteltu toiminto jos käytetään pakkausta TRE700 720 katso linkitysohje 2 Aseta potentiometri asentoon...

Reviews: