BODYGUARD-T
Installation Instructions
I-EA00206
Rev 01, Rev Date: 05/08/2018
Page
9
of
12
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
10. UNIVERSAL REMOTE CONTROL (cont.)
THRESHOLD
: The Threshold is always OFF when the door is closed.
PATTERN WIDTH OR DEPTH
: When pattern width or depth is changed, a set-up of the new pattern size will automatically be triggered
once a value key has been pressed.
Pattern Width
(Door Open/Closed)
1: Wide (closed door)
2: Middle (open door)
3: Asymmetric Left Narrow
4: Asymmetric Right Narrow
5: Narrow Left
6: Narrow Right
7: Asymmetric Left Wide
8: Asymmetric Right Wide
9: Center Narrow
See notes for PATTERN WIDTH or
DEPTH below.
Pattern Depth
1: Deep – threshold ON
2: Medium – threshold ON (open)
3: Limited – threshold ON
4: Deep – threshold OFF
5: Medium – threshold OFF (closed)
6: Limited – threshold OFF
See THRESHOLD note below.
See PATTERN WIDTH or DEPTH note
below
Sensitivity
(Door Open/Closed)
0
(min)
®
9
(max)
(default 7 for door open, default 6
for door closed)
Immunity
1: Low (Normal)
2: Medium – Rain (disregards more floor disturbances)
3:
High – Snow (disregards greatest floor disturbances)
NOTE: For BODYGUARD-TC functionality, set
Immunity to 3-HIGH.
Automatic Learn
Time
0: 30 seconds
1: 1 minute
2: 2 minutes
3: 3 minutes
4: 5 minutes
5: 7 minutes
6: 10 minutes
7: 15 minutes
8: 10 seconds
9: Infinity – no learn
Modes of Operation
0: Normal
1: MP mode
2: Record mode