Paired Operators
When wiring controls for use as a simultaneous pair, all required inputs need to be sync’d (connected)
between Door #1 and Door #2 (shown as dotted lines in below diagram).
Example shown below: Push plates are connected to inputs 8, 10 and 11 at door #1 and are connected
via sync line to Door #2.
When using pairs of controls, inputs 12, 13 and 14 may be sync’d to each other, OR each control may
have it’s own jumpers installed. If any of these inputs are required for the application, the jumper will
be removed for the respective input – in place of the jumper, a N.C. switching circuit will connected to
Door #1, and a sync line will be connected to Door #2.
For simultaneous pairs, Hager provides a dual harness standard for the On-Off-Hold switch. Each plug-
in connector for the control is wired in parallel to the On-Off-Hold switch located in the header end-cap.
One switch will control both doors.
All control adjustments (speed & time delay) must be made independently at each control.
All dipswitches at each control must be set independently and must match between controls.
When using the optional programmer, settings must be made independently at each control and must
match between controls.