background image

8300 Low Energy Auto-Operator 

Installation Instructions

I-EA00257 / 26790910

Rev 2, Rev Date: 1/30/19

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

Commisioning

The commissioning step allows the operator to learn the door weight, motion, and stop location.  

This step must be performed on all new installations or anytime the operator stroke is altered 

in any way.

To begin commissioning…

1.

 Ensure main power is on.

2.

 Verify the adjustment board dip switches SW2 are set as desired.

3.

 At the I/O control board, press the SW1 button for approximately 5 seconds. When the red LED (DL2) 

on the Adjustment Board begins flashing rapidly, release the button.

 

If the red LED (DL2) does not start flashing, verify that you are pressing the SW1 button on the I/O 
control board and not the SW1 button on the Adjustment Board.

4.

 The door will slowly open, recycle partially, close and re-open.

5.

 Do not interrupt the process and do not move the door manually during this time.

6.

 If the door does not open and the red LED (DL2) is flashing slowly, verify that the motor is plugged in 

properly at the control board.  Correct as necessary.

7.

 Once commissioning is complete, the door will close and the LED will go out.

8.

 Commissioning complete.

9.

 Upon commissioning completion, activate the door to open and ensure all performance is acceptable.

 

Adjust opening/closing speeds and hold open time as required. 

 

DL4 will illuminate yellow anytime a change has been made to the control, such as speed or time 
adjustment.  Momentarily press Adjustment Board SW1 to acknowledge the change and extinguish 

the yellow LED.

 

If speeds or hold open time are changed, a re-learn is not required.

Notes:

 

A re-learn is not required following a main power recovery.

 

Speed and time adjustment changes will not take effect until the door closes fully after the adjustment 
has been made.

 

Additional adjustments are available with the Hager programmer (part number 2-679-0907)

Page 12 of 18

Summary of Contents for 8300 Series

Page 1: ...agerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 The manufacturer s specifications for this product require the installation to be approved by an AAADM certified inspector Installation and Service Manual 8300 Series Swing Door Operators Page 1 of 18 ...

Page 2: ...d and adjusted OWNER INFORMATION TO BE PROVIDED BY THE DISTRIBUTOR INSTALLER After the installation instruct the owner on the safe operation of the door Location and proper use of the power switches Location of the main cutoff breaker Necessary warnings not covered in general instructions Owner s Manual and Daily Safety Checklist Phone number s for the local servicing dealer What to do in the even...

Page 3: ...ns Fused Protection Weight Ambient Operating Temperature Ingress Protection Push Arm Pull Arm 36 Door 438 lbs 342 lbs 42 Door 328 lbs 256 lbs 44 Door 299 lbs 234 lbs 48 Door 254 lbs 198 lbs 24 VDC Accessories Power Supply 24 VDC Electric Lock Power Supply Adjustable Speeds Timers Standard Selector Switch Functions Standard Control Outputs Standard Control Inputs Maximum Door Weight 115 VAC 6 10 60...

Page 4: ...ith bottom of door frame Pull side mounting Back Plate should be mounted 1 5 up from bottom door frame Back plate should overlap each jamb tube by 1 5 Refer to page 13 for fire rated door applications 4 Re install operator drive module per handing charts on page 6 1 5 2 1 16 4 5 4 75 4 5 4 75 2 1 16 4 5 4 75 4 5 4 75 2 3 8 Push Arm 35mm Spindle Hollow Metal Frame 5 8 Stop Height Push Arm 35mm Spin...

Page 5: ...configuration The keyhole allows for easy removal of the drive plate without the need to loosen the screw Removing the four 4 screws allows the drive plate and operator to be removed from the header and rotated 180 degrees to change from a push to a pull or vice versa 1 Loosen the four 4 mounting screws using a 5mm hex wrench and slide each one off the drive plate 2 Remove drive plate by shifting ...

Page 6: ...TRACK ARM Operator is non handed Handing is determined by operator mounting orientation inside header Push I O Board Towards Hinge Jamb and SW2 Dip Switch 2 OFF see page 6 Pull Round Motor Towards Hinge Jamb and SW2 Dip Switch 2 ON see page 6 INTERIOR EXTERIOR INTERIOR EXTERIOR LHR RHR LH RH LH INTERIOR EXTERIOR INTERIOR EXTERIOR LHR RH RHR Drive plate mounting screw Locating Screw Do not remove t...

Page 7: ...pindle to the primary arm make sure to install the spindle mounting bolt 3 Attach the primary door arm approx 20 degrees past perpendicular and towards the closing direction as shown If more spring tension is desired simply increase the mounting angle to greater than 20 degrees so it results in increased preload Adjust the secondary telescopic arm to the prescribed length according to chart Door R...

Page 8: ...the door at the proper location from the hinge end of the door as shown below 2 To install the pull arm the operator must be powered to the full open position as it is not possible to install the arm in the closed position as to allow proper preload 3 Power the door to the open position through the use of the hold open switch on the side of the header It may be necessary to first execute a setup o...

Page 9: ...his step may be optional depending on your application CAUTION DO NOT REMOVE THE STOPS The mechanical stops are located on the top or bottom of the operator depending on the door handing The stops are default set to maximum opening and closing angles To adjust the stops loosen the bolts indicated below with a 5 32 wrench or pliers and slide the stop in the track to the desired stop location It is ...

Page 10: ...rm as well as voiding the warranty Connect the main power to the Black White Green conector on the back plate Main power supply 120VAC 15A Single Phase 60hz Attach the incoming 120VAC line to the wiring provided in the header shown below DO NOT TURN POWER ON until all remaining wiring has been completed BLACK 120VAC Power WHITE Neutral GREEN Ground Upon applying power observe the adjustment board ...

Page 11: ...minal Strip J3 Programmer Terminal Strip J6 Auxiliary Terminal Strip DS2 NOT USED SW1 Commisioning Button DS1 NOT USED I O Control Board J6 Unpowered Closing Speed Jumper TR1 Opening Speed Adjustment TR2 Closing Speed Adjustment TR3 Hold Open Time Adjustment TR4 Unpowered Closing Speed Adjustment DL1 LED Green DL2 LED Red DL3 LED Blue SW1 Parameter Change Switch DL4 LED Yellow SW2 10 Function Dip ...

Page 12: ...l slowly open recycle partially close and re open 5 Do not interrupt the process and do not move the door manually during this time 6 If the door does not open and the red LED DL2 is flashing slowly verify that the motor is plugged in properly at the control board Correct as necessary 7 Once commissioning is complete the door will close and the LED will go out 8 Commissioning complete 9 Upon commi...

Page 13: ...ach control may have it s own jumpers installed If any of these inputs are required for the application the jumper will be removed for the respective input in place of the jumper a N C switching circuit will connected to Door 1 and a sync line will be connected to Door 2 For simultaneous pairs Hager provides a dual harness standard for the On Off Hold switch Each plug in connector for the control ...

Page 14: ...o the hollow metal door frame ensure there are 5 attaching screws spaced equally apart They should be 12 sheet metal type screws Fire rated power operated doors must close and latch during a fire alarm condition Ensure proper procedures have been followed to allow a main power disconnect during a fire alarm condition Always check to ensure compliance to local building codes Upon job completion alw...

Page 15: ...ds hold open 5 seconds to close Speed time potentiometers are disabled Settings are fixed Control can be adjusted for low energy operation via potentiometers Default 6 Lockout Function Overhead presence sensor input 17 is inhibited during closing cycle unless input 17 is triggered Connect COM and input 14 to NC output of lockout safety beam Disabled Overhead presence sensor input 17 is inhibited d...

Page 16: ...Ground 8 GND Common Ground 9 24VDC 1 A Max Current 10 Internal Activation Requires N O Contact between input 10 GND Remains capable to activate when dip switch 3 is ON AND On Off switch is OFF 11 External Activation Requires N O Contact between input 11 GND 12 Emergency Closing Requires N C contact between 12 GND Upon open contact door closes and overrides all other inputs Remains jumpered if inpu...

Page 17: ...R 24VDC WHITE RED Fail Secure Fail Safe NOTE USE EITHER FAIL SAFE OR FAIL SECURE CONNECTION DO NOT USE BOTH ON 1 2 12 24V AC DC COM N O N C RELAY ACTIVATION LED RECEIVE R LEARN LED MLR WHT WHT N O COM N C INTERIOR N O COM N C EXTERIOR Hager Electric Strike 2930 pictured Hager Wireless Receiver Part 2 659 0183 Hager Wireless Transmitters Part 2 659 0185 Hager Actuator Plates Hager 8300 Operator I O...

Page 18: ...tensioner refer to Appendix for chain tensioner adjustment procedures o Launch a new setup If problem repeats and there are no other discrepancies noted replace the operator control sub assembly Door closes too fast at last 5 to 10 degrees of closing Ensure dip switch 8 is OFF Ensure there is no binding of the door as it is closing through the last few degrees of closing If binding exists from a t...

Reviews: