11
OPERATION MANUAL
Place the machine near an existing power source. Make sure all power cords are protected from
traffic, material handling, moisture, chemicals, or other hazards. Make sure there is access to a
means of disconnecting the power source. The electrical circuit must meet the requirements for
240V.
NOTE : The use of an extension cord is not recommended as it may decrease the life of electrical
components on your machine.
3.5 ELECTRICAL INSTALLATION
ELECTRICAL REQUIREMENTS
Nominal Voltage......................................... 240V
Cycle............................................................ 50 Hz
Phase............................................... Single Phase
Power Supply Circuit.............................10 Amps
Full Load Current................................. 6.0 Amps
(Full load current rating is also on the specification plate on the motor.)
3.4 MACHINE LEVELING
To set your machine up so that it operates to optimum performance, apply the following
procedure
After your machine has been anchored to a concrete slab floor, it then needs to be leveled.
Loosen the hold down bolts and place a level on the surface of the working table. Metal shims
need to be placed under corner of the base of the machine until level. Once level then tighten
the hold down bolts. (Fig. 3.3).
The machine must not rest on supports
other than those defined in Fig. 3.1
Metal Shim
Hold Down Bolt
F
ig
. 3.3
Page 11
Instruction Manual for EB-260V (B062V)
04/04/2019