Summary of Contents for ELAN HS-5100

Page 1: ...HS 5100 HS 5200 HS 5400 ANALOGUE ADDRESSABLE CONTROL PANELS User Manual Approved Document UI ELAN 02 Revision 03 www acornfiresecurity com www acornfiresecurity com...

Page 2: ...Page 2 of 42 This page is intentionally blank www acornfiresecurity com www acornfiresecurity com...

Page 3: ...le Conditions_____________________________________________________ 18 3 8 Menu Functions _______________________________________________________ 19 3 8 1 Using the Buttons to Navigate Menus __________...

Page 4: ...___________________________________________________________ 34 3 13 1 Test Zones ______________________________________________________ 34 3 13 2 Test Display__________________________________________...

Page 5: ...nt Investigation Delays to Outputs Dependency on more than one alarm signal Fault Signals from Points Disablement of Points Alarm Counter Test Condition Standardised Input Output EN54 4 1997 A1 2002 A...

Page 6: ...Mx 5000 Mx 5000N Series Fire Alarm Control Panels Refer to the Installation and Commissioning Manual Document No 680 165 for details of how to install and program the panel 1 3 1 HS 5000 Series The H...

Page 7: ...n DELAYED POWER TEST FIRE SYSTEM FAULT SOUNDER DISABLED FIRE PROTECTION ACTIVATED EVACUATE RESOUND LED TEST RESET MUTE SILENCE ESC MENU WXYZ TUV PQRS GHI JKL MNO DEF ABC MOREALARMS DISABLE FAULT FIRE...

Page 8: ...ults and warnings It also shows menus for use when inspecting or programming the operation of the panel Under normal conditions the panel display shows the access level time date and status HS 5000 LE...

Page 9: ...d Red Indicates that the circuit to fire extinguishing or other fire protection equipment has been activated or that the fire protection equipment itself has been activated Sounder Silenced Yellow Ind...

Page 10: ...h Level 2 Access Resound Press to re activate the sounders Only available with Level 2 Access Evacuate Press to initiate a manual evacuation and sound the alarms Only available with Level 2 Access LED...

Page 11: ...4 Service and Maintenance Engineer Special Tools required A Level 1 Untrained User can view the current operational condition of the system and may MUTE the internal buzzer NOTE Depending on the confi...

Page 12: ...ach number is entered an asterisk is shown on the display For example CONTROLS DISABLED Please Enter Your Password If the password is correct the Level 2 Menu options will be shown If the password is...

Page 13: ...INT Location Text for First Zone Location Text and Type of Device 2 Zones in Fire Last Zone 0005 BASEMENT EAST No of Zones in Fire Last Zone Zone Description for Last Zone Press the MUTE button to sil...

Page 14: ...to the previous display If no button is pressed within 15 seconds the display automatically reverts to the main display 3 2 2 Investigation Delays The Investigation Delay Function can be disabled or e...

Page 15: ...the appropriate fault Status Indicators and Display information Press the MUTE button to silence the internal buzzer The display then shows the current time and date and service centre telephone numbe...

Page 16: ...lement condition and location text Press the buttons to highlight the required option and then press the button to view further information 3 4 1 Disabled Inputs The display presents a list of all of...

Page 17: ...hows that the panel sounder circuits are disabled Press the button to view further information including type value and state etc Outputs in Zone 0100 More Mode Type Disabled SOUNDER Disabled SOUNDER...

Page 18: ...pre alarm fault disablement warning security and supervisory conditions simultaneously the display shows these in the lower half in priority order The detail of the most recent unacknowledged conditi...

Page 19: ...zone or an individual input Outputs 2 Disable sounder outputs or other devices Controls 3 Cancel Level 2 access User ID 3 Return Level 2 access to the default User 1 Groups Disable a user defined disa...

Page 20: ...vert to the normal operating display Press the Menu button to return directly to the Level 2 Menu display previously shown 3 8 1 2 Selecting Individual Zone Numbers When the display is showing a list...

Page 21: ...ntly in a Fault condition The operation of the panel and the information that can be shown is identical to the views available from the main operating display Refer to Section 3 3 for further informat...

Page 22: ...erational condition for all Outputs Outputs More Zone Location 0002 Reception 0003 Ground Floor 0013 First Floor Corridor 0014 First Floor Press the buttons to highlight the required zone and then pre...

Page 23: ...its optional interface cards 3 9 7 1 Software Software PANEL DISPLAY LOOP CARDS NETWORK PSU PERIPHERAL PRINTER Panel Software Software PROGRAM ID HS5000 050 04 CHECKSUM 92879016 Other Software Select...

Page 24: ...al Earth Volts 0V 30V 2 5V 14 5V 6 Normal Too High Too Low System Volts 19V 30V 28 0V Normal Aux Load 0mA 500mA 5 Normal Too High 1 st Loop Load 7 0mA 500mA 5 Normal Open Circuit Too High Short Circui...

Page 25: ...s the buttons to highlight the required menu option and then press the button to select it The display then shows the appropriate list of events 3 9 8 1 Event Log The display will always show the most...

Page 26: ...Pressing 0 allows the stored network status information to be cleared 3 9 10 View Warnings This Option can be used to obtain information about warning conditions on the panel A warning condition is cr...

Page 27: ...RECEPTION AREA Press the buttons to scroll through the available zones or key in a specific zone number To disable the entire zone move over to the Mode column and highlight the existing mode Press th...

Page 28: ...ll be illuminated 3 10 2 2 All Beacon Outputs Press the buttons to scroll through and highlight the ALL BEACONS Option and then press the button to disable them The display automatically reverts to th...

Page 29: ...will cancel Level 2 access and return the panel to Level 1 operation If the panel has an access key switch fitted use the key switch in preference to the menu option shown below Disable User 1 Node 1...

Page 30: ...oups Disablement Groups are a means of disabling enabling custom groups of devices The commands are command across the network of panels and can be invoked from any panel The installer will have confi...

Page 31: ...led The individual outputs within the zone can then be enabled The display format is virtually identical to the Disable displays 3 11 3 Enable Groups This option allows the re enabling of User defined...

Page 32: ...tigation delays in operation If the investigation delays are in operation then the Delayed LED Indicator is illuminated When the investigation delays are turned off the Delayed LED Indicator is turned...

Page 33: ...ing holiday periods On selection the display shows Inhibit Delay End Date TIME 15 49 DATE 02 07 08 WED 02 JUL 2008 Press the buttons to select the time date fields Enter the required time and date usi...

Page 34: ...commissioning to define which of the sounders are activated during a test The display then shows a list of the available Zones and their current test status For example 0 Zones in Test Zone Test State...

Page 35: ...ISHED TEST option will cancel all zone tests The Test LED will then extinguish Alternatively it is possible to leave the Zone Test Function with one or more Zones still in Test by selecting the KEEP Z...

Page 36: ...ANT ROOM 0100 MAIN RECEPTION Press the buttons to scroll and highlight the required zone or key in the required zone number and then press the button to show the output devices in that zone For exampl...

Page 37: ...utton to confirm If the current User ID does not have the necessary permission the display prompts for entry of a password to guard against inadvertent changes Enter the password as normal The display...

Page 38: ...er Loop and address current status and analogue value 3 14 1 4 Print Outputs To print information on any output highlight the Outputs option and press the button to confirm The display will show the f...

Page 39: ...as required Press the key to start printing The printout will show the location and state of all input and output points in a disabled condition for the zones selected The display always present the z...

Page 40: ...JAN 2009 To change the settings use the buttons to highlight the required option Directly enter the new time or date using the number buttons As soon as a number button is pressed the display will cle...

Page 41: ...Page 41 of 42 USER NOTES www acornfiresecurity com www acornfiresecurity com...