Maintenance
24
5.52.291.00.01.01
12 Maintenance
Pos: 16.2.1 /1_HADEF/12-INSTANDSETZUNG/Allgemein/01.Allgemein @ 0\mod_1173251926256_52.docx @ 469 @ @ 1
12.1 General
All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment;
they must be effected with utmost care.
Only “qualified persons” may do this work.
Servicing and maintenance work must only be done when the hoist is not loaded.
Records must be kept of all test results and measures taken.
Pos: 16.2.2 /1_HADEF/12-INSTANDSETZUNG/Allgemein/02.Überwachung @ 0\mod_1173254503420_52.docx @ 472 @ @ 1
12.2 Monitoring
The monitoring and servicing intervals stated are valid for operation under normal conditions and single-shift
operation. In case of severe operating conditions (e.g. frequent operation with full load) or special
environmental conditions (e.g., heat, dust, etc.), the intervals must be shortened correspondingly
Pos: 16.3.1.1 /1_HADEF/12-INSTANDSETZUNG/Druckluftmotor/Tabellen/Tabelle - alle @ 1\mod_1193146811619_52.docx @ 8142 @ @ 1
12.3 Pneumatic
motor
The thickness of the brake lining must be checked at least once a year.
Check the function of the brake daily.
Assembly and disassembly of the brake lining (1) must only be effected by a "trained expert".
When the wear limit thickness of the brake linings is reached, the linings including their carrier must be
exchanged.
Adjustment is not possible.
Only use original spare parts.
Motor output
kW
brake lining
thickness
B min.
mm
0,52-0,75
6,0
1,5-2,5
6,5
Illustration 13
Pos: 16.4.1 /1_HADEF/12-INSTANDSETZUNG/Überlastsicherung/Druckbegrenzungsventil/Druckbegrenzungsventil @ 1\mod_1193151214195_52.docx @ 8159 @ @ 1
12.4
Overload protection by pressure limiting valve
Factory setting for the desired load at 6 bar.
Normally this setting does not need to be
adjusted.
Illustration 14
Pos: 16.5.1 /1_HADEF/12-INSTANDSETZUNG/E+P - Winde - Zubehör/Seilwegbegrenzungsschalter/Seilwegbegrenzungsschalter - Einstellung @ 0\mod_1175610018408_52.docx @ 3077 @ @ 1