C A U T I O N
Indicates a potentially hazardous situation that may result in minor or moderate injury.
N O T I C E
Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special
emphasis.
Precautionary labels
Read all labels and tags attached to the instrument. Personal injury or damage to the instrument
could occur if not observed. A symbol on the instrument is referenced in the manual with a
precautionary statement.
This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid potential
injury. If on the instrument, refer to the instruction manual for operation or safety information.
This symbol indicates that a risk of electrical shock and/or electrocution exists.
This symbol indicates the presence of devices sensitive to Electro-static Discharge (ESD) and
indicates that care must be taken to prevent damage with the equipment.
This symbol, when noted on a product, indicates the instrument is connected to alternate current.
Electrical equipment marked with this symbol may not be disposed of in European domestic or
public disposal systems. Return old or end-of-life equipment to the manufacturer for disposal at no
charge to the user.
Products marked with this symbol indicates that the product contains toxic or hazardous substances
or elements. The number inside the symbol indicates the environmental protection use period in
years.
Product overview
The sensor cleaning and regeneration center is a multi-purpose device for ORBISPHERE sensors.
The product performs these important functions:
• It offers a rapid and efficient method for cleaning sensor electrodes, and in the case of hydrogen
sensors a method of cathode re-chloridization or regeneration.
• It allows a simple check to be made on the circuitry of most sensors to make sure that the sensor
is working correctly, or alternatively trace a fault.
The product consists of two parts:
• The unit itself (
Figure 1
).
• A regeneration cell with an attached banana plug (
Figure 2
).
The regeneration cell DG33619 is applicable to clean A1100 or C1100 sensors (
Figure 3
).
Note: Two additional banana plugs are supplied to connect to the ohmmeter leads should they need to be adapted
for use with the unit when testing circuits.
Electric power (
No. 1
in
Figure 1
) is required for the cleaning functions of the unit. It is pre-configured
for either a 120 V or a 230 V power supply so check to see that the right voltage has been specified
for your needs. Electric power is not needed for the circuit test functions.
The 10-pin LEMO plug cable (
No. 3
) is used to connect the unit to a sensor for cleaning and circuit
testing. The sensor 10-pin LEMO receptacle (
No. 6
) fulfills the same function. For sensors with
detachable cables use the unit cable leaving your sensor cable in place and attached to the
4
English
Summary of Contents for ORBISPHERE 32301
Page 2: ...English 3 Deutsch 12 Fran ais 22 Espa ol 32 Italiano 42 Nederlands 52 Svenska 62 Suomi 71 80 2...
Page 81: ...ORBISPHERE 1 2 DG33619 A1100 C1100 3 81...
Page 82: ...1 1 120 230 10 LEMO 3 10 LEMO 6 1 32301 1 120 230 5 2 6 3 7 4 5 60 4 7 2 LEMO 82...
Page 87: ...1 2 3 4 70 30 5 6 1 2 3 Hach Lange TEST 87...
Page 90: ......
Page 91: ......