HAC-LBee/S manual V3.X SHENZHEN HAC TECHNOLOGY CO., LTD.
FAX:+86-755-23981007 E-MAIL
:
-
17 -
Command
ATCN(
Exit Command Mode
)
Parameter
None
Effective Conditions
Validate immediately
Minimum Firmware Version Required
:
0x19
5.2.5 DH
<Networking {Addressing}> The DH command is used to set and read the upper 32 bits of the RF
module's 64-bit destination address. When combined with the DL (Destination Address Low)
parameter, it defines the destination address used for transmission.
Under transparent mode, HAC-LBee/S sends data with this destination address. When the
destination address (DH + DL parameters) is
0x000000000000FFFF
, HAC-LBee/S will send the
data through broadcasting. When the 64-bit destination address is less than 0x000000000000FFFF,
HAC-LBee/S will send the data according to the 16-bit destination address.
Only under the transparent mode, and DT=0, the setting will be effective.
Command
ATDH (
Destination Address High
)
Range
0x00 - 0xFFFFFFFF
Parameter
Default Value
0x00
Effective Conditions
Validate immediately
Minimum Firmware Version Required
:
0x1000
The examples for changing the upper 32-bit of destination address:
Input 3-character command sequence
“
+++
”
and switch to the AT Command mode.
Using ATDH command to setup the upper 32-bit of destination address you want, such as ATDH
0<CR>.
Using ATWR command to write the setting into Non-volatile memory
Input
“
ATCN<CR> command to exit from the AT Command mode.
5.2.6 DL
<Networking {Addressing}> The DL command is used to set and read the lower 32 bits of the RF
module's 64-bit destination address. When combined with the DH (Destination Address High)
parameter, it defines the destination address used for transmission.
Under transparent mode, HAC-LBee/S sends data with this destination address. When the
destination address (DH + DL parameters) is
0x000000000000FFFF
, HAC-LBee/S will send the
data through broadcasting. When the 64-bit destination address is less than 0x000000000000FFFF,