Faults and causes
Solution
6. Exhaust gases leaking:
a) The supply pressure is too low
b) Blockage or backward flow in the chimney
c) Conditions in the building such as
windows and doors (too well) sealed. If for
example a door is opened, this causes a
temporary pressure drop in the room and the
chimney no longer draws air.
d) Exhaust gas leaking from the flue door when
opened.
e) Extractor hood is switched on.
Seek advice from a chimneysweep
See also 2b)
Close or open doors and windows
more slowly
Open flue door more slowly
7. Cinder buildup:
a) Overload of the stove by heating
with an open flue door
b) Non-combustible components in the
fuel.
Close the flue door
Choose better fuel
8. Explosion
a) Temporary blockage or backward flow in the
chimney
b ) Flues or exhaust gas pipe clogged with soot.
See also 6b) and 6c)
Clean flues and exhaust gas pipe
For
cleaning and maintenance of the stainless steel parts
please use only the special products available
through the trade. In no circumstances should scouring or abrasive media or objects be used!
Please understand that visits by Customer Service cannot be made free of charge even during the
guarantee period if the device is not working correctly because of incorrect operation.
Right to make technical changes reserved!