Failures, failures
Failures and failures:
1.
Unpleasant smell, withering of
the protective coating
Workaround:
Heat the oven for several hours.
2.
Not effective heating of the
oven
a) Too low delivery pressure
(Chimney air draught)
b) Air control is closed
c) Too long and leaky exhaust pipe
3.
Heating is too strong
a) Heating door is not tight closed
b) The sealing of the heating door is
damaged
c) Draft regulator max open
Normal use
a.) The delivery pressure should be ca.
12 Pascal. Inspect the thickness of
chimney. Close the open doors of other
devices connected to the same chimney.
Close the fireplace tight.
b.) Adjust the regulator to 100%.
c.) Close the open chimney cleaning holes.
All exhaust pipe connections must be
sealed.
a.) Air control is open too much. Close
the door tight.
b.) Install new sealing.
c.) Draft regulator adjust to 30%.
Failures and failures:
Workaround:
4.
a) Oven performance cannot be
adjusted to adequately low
– endurance
burning is not possible.
a)
Heating door is leaky
a) The correct setting for slow
combustion depends on the fuel
used and the available supply
pressure
– must be tested.
b.) Close the door tight, check the sealing,
if needed change it.
5.
Insufficient performance of the oven:
a
Air draught of oven is not good,
exhaust pipes are clogged with
ash/soot
b.)
Ash or cinder hinder the entry of
combustion air
19
a.) Clean air tractions and exhaust pipe.
b.) Clean the grates of residues. Regularly
shake off the grill with poker. Empty the
ash pan at least once a day.