16
○
The hole depth should be the anchor length plus the bit length. Each hole should have
the same depth. Remove the dust from the hole before measuring the hole depth. Use
a vacuum cleaner to prevent dust from spreading.
○
If the wall surface is too solid and slippery to position the bit, punch a notch first.
3.
Remove dust inside and around all holes with a vacuum cleaner, and then measure the
distance between holes. If there is an error, mark and drill holes again.
4.
Put an anchor into each hole vertically and tap the flat end of the anchor with a rubber
hammer until the anchor is flush with the wall surface.
5.
To affix the wall-mounting bracket, align the three holes in the wall-mounting bracket with
the anchors and insert three expansion screws through the installation holes into the
anchors. Adjust the position of the wall-mounting bracket and tighten the expansion
screws.
6.
Affix the AP using one of the following two methods:
Method 1: Align the two installation holes in the AP with the corresponding holes in the
wall-mounting bracket and then use two screws to affix them.
Method 2: Insert a screw into each installation hole in the AP, but do not tighten them.
Then insert the screws into the corresponding holes in the wall-mounting bracket.
7.
Tighten the screws so that the AP touches the wall-mounting bracket (see Figure 11
Figure 11
Install the outdoor AP on a wall
Installing the AP on a pole
The fixing support for installing the outdoor AP on a pole consists of two major components: a pair of
V-shaped brackets and a mounting plate. The outdoor AP can be affixed on a vertical or horizontal
pole with an outer diameter of 60 to 110 mm (2.36 to 4.33 in) through the affixing support. The mounting
plate and the V-shaped bracket are affixed through the self-clinching bolt and a nut (see Figure 12 You
can first install the affixing support onto the pole and then the AP onto the mounting plate or vice versa.
Screw M6×12