The AP does not hinder people’s daily work and life. 

 

The place is not water seeping, water soaking, and condensing. 

 

The AP is more than 5 m (16.40 ft) away from 3G and 4G stations and antennas. 

Installing the AP 

The AP can be installed only indoors. You can mount the AP on a table or a wall. 

Mounting the AP on a table 

Figure 4 Mounting the AP on a table 

 

 

Mounting the AP on a wall 

1. 

Mark the installation holes on the wall. 

Figure 5 Marking installation holes on the wall 

 

 

56 mm

(2.20 in)

Summary of Contents for UAP380

Page 1: ...H3C UAP380 Access Point Installation Guide New H3C Technologies Co Ltd http www h3c com hk Document version 5W100 20180126...

Page 2: ...r trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has been made in...

Page 3: ...guments that you replace with actual values Square brackets enclose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bar...

Page 4: ...topology icons Convention Description Represents a generic network device such as a router switch or firewall Represents a routing capable device such as a router or Layer 3 switch Represents a generi...

Page 5: ...cumentation To access the most up to date H3C product documentation go to the H3C website at http www h3c com hk To obtain information about installation configuration and maintenance click http www h...

Page 6: ...3 Pre installation tasks 3 Determining the installation position 3 Installing the AP 4 Mounting the AP on a table 4 Mounting the AP on a wall 4 Connecting the AP to the power source 7 Check after powe...

Page 7: ...on Take adequate safety measures to avoid body injury and AP damage Place the AP in a dry and flat location and take anti slip measures Keep the AP clean and dust free Do not place the AP in a moist a...

Page 8: ...2 Installation tools When installing the AP you might need the following tools Prepare the installation tools as required Figure 2 Installation tools...

Page 9: ...r information about AP LEDs see Appendix B Ports and LEDs Cabling has been completed where the AP is to be installed Record the MAC address and serial number of the AP for future use Determining the i...

Page 10: ...6 40 ft away from 3G and 4G stations and antennas Installing the AP The AP can be installed only indoors You can mount the AP on a table or a wall Mounting the AP on a table Figure 4 Mounting the AP o...

Page 11: ...l 3 Insert a screw anchor into each hole and tap it with a rubber hammer until it is flush with the wall surface Figure 7 Hammering the anchor 4 Fasten a screw into each screw anchor Do not fasten the...

Page 12: ...screws Slide down the AP to secure it in place Figure 9 Mounting the AP on the wall 6 Use two screw anchor and screw sets to mount the power adapter bracket on the wall and then slide the power adapt...

Page 13: ...nd then attach the power cord retainer to the AP Figure 11 Attaching the power cord Figure 12 Installation completed Connecting the AP to the power source The AP supports only a local power source You...

Page 14: ...erify that the AP is operating correctly For information about AP LEDs see Appendix B Ports and LEDs Connecting the AP to an IoT module An IoT port can connect only to IoT devices if power supply is e...

Page 15: ...Installing an antenna Before installing an antenna change the antenna type to external at the CLI Attach an antenna to the AP fasten the connector on the antenna and change the antenna orientation to...

Page 16: ...Total number of connected APs 1 Total number of connected manual APs 1 Total number of connected auto APs 0 Total number of connected common APs 1 Total number of connected WTUs 0 Total number of insi...

Page 17: ...cation Protocol IEEE802 11a b g n ac wave2 Radios Two Built in antenna 2 4 G antenna gain 3 dBi 5 G antenna gain 5 Bi Power consumption 20 W when no power is being supplied 90 W when power is being su...

Page 18: ...et copper port IoT port One USB port Two SMA antenna ports One SFP fiber port The AP also has a security slot The security slot is 7 3 mm 0 28 0 12 in in size Figure 16 Ports on the AP 1 and 7 SMA ant...

Page 19: ...are interfaces GE1 0 5 through GE1 0 7 at the CLI 100 1000 Mbps Ethernet copper port IoT port 8 IEEE802 3 IEEE802 3u Acts as an IoT interface to connect to T300M X or T300M B wireless IoT access units...

Page 20: ...d clients Off No clients are associated with the AP or the LED has been turned off from the CLI PSE port LED Yellow Steady on The PSE port is supplying power incorrectly Green Steady on The PSE port i...

Page 21: ...AP to the power source 7 D Determining the installation position 3 I Installation flowchart 3 Installation tools 2 Installing an antenna 9 Installing the AP 4 L LEDs 13 P Ports 12 Pre installation tas...

Reviews: