62
LED Status Description
Fast flashing (8 Hz)
The card is loading software or has not started.
LINK/ACT
Off
No link is present.
Steady green
A link is present.
Flashing
The port is sending or receiving data.
M1SSICASK1 security situation intelligent computer node
module LEDs
The NSQM1SSICASK1 security situation intelligent computer node module provides LEDs to
indicate the operation status for the module and the hard disk.
Table 37 NSQM1SSICASK1 LED description
LED Mark
Status
Description
System power
LED
Steady green
The system has started.
Flashing green
The system is starting.
Steady amber
The system is in standby state.
Off
No power input or the module is faulty.
System run
LED
Steady green
The system is operating correctly.
Flashing green
HDM is initializing.
Flashing green and
yellow
A general alarm has occurred, including HDM
alarms and hardware alarms.
Flashing yellow
A severe alarm has occurred, including HDM
alarms, hardware alarms, and processor alarms.
RUN
Steady green
The module is faulty.
Flashing green (1
Hz)
The module is operating correctly.
Off
The module is faulty or is not present.
UID button
LED
UID
Steady blue
UID LED is activated.
Flashing blue (1 Hz)
The firmware is being upgraded or the system is
being managed from HDM.
Flashing blue (4 Hz)
HDM is restarting.
Off
UID LED is not activated.
LEDs of other service modules
Other service modules than the NSQ1FWCEA0 and NSQM1SSICASK1 provide LEDs to indicate
the operation status for the module and the hard disk.