5-37
Field
Description
which indicates the physical memory available for applications.
Swap
Swap memory.
Displaying the operational status of power
supplies
Use the
display power
command to display the operational status of power supplies.
<Sysname> display power
Power 0 Status: Normal
Power 1 Status: Absent
Table5-4 Output description
Field
Description
Power
Number of the power supply.
Status
Power supply state:
•
Normal
—The power supply is operating correctly.
•
Absent
—The power supply is not in position.
•
Abnormal
—The power supply has failed.
Displaying the temperature information of the
firewall
Use the
display environment
command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Slot Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit
Shutdown-UpperLimit
1 inflow 1 28 -2 52 60
NA
1 outflow 1 31 0 55 65
NA
1 hotspot 1 42 0 70 78
NA
Table5-5 Output description
Field
Description
Sensor
Temperature sensor:
•
inflow
—Air inlet vent temperature sensor.
•
outflow
—Air outlet vent temperature sensor.
•
hotspot
—Hotspot temperature sensor.
Temperature
Current temperature.