10
Troubleshooting flowchart
Figure 3 Troubleshooting IRF fabric establishment failure
Solution
To resolve the issue:
1.
Verify that the number of member devices does not exceed the upper limit.
If you are adding a new member device to an existing IRF fabric or merging IRF fabrics, use the
display irf
command to identify the number of member devices in the IRF fabrics. If the total
number of member devices exceeds the upper limit, the IRF setup will fail.
No
Yes
No
Yes
No
Yes
IRF setup
failure
No
No
Yes
Yes
No
Yes
Resolved?
No
Yes
Yes
No
Yes
No
Yes
You cannot add devices to the
IRF fabric
Yes
No
Member ID unique?
Modify IRF port bindings or
reconnect physical ports
Number of members
fewer than the upper limit?
IRF port bindings
or physical IRF connections
correct?
No
Resolved?
10-Gbps or 40-Gbps IRF links used?
Replace with 10-Gbps or 40-
Gbps transceiver
modules/cables
Resolved?
(Optional.)
Transceiver modules at link ends are
the same type?
Replace the transceiver
modules to be the same type
Resolved?
IRF links up?
Bring up the IRF links/activate
IRF port configuration
Resolved?
Assign a unique member ID to
each member device
Contact H3C
Support
End
Same software version?
Upgrade software to the same
version in the fabric
Resolved?
No
Yes
No
Yes