4-5
Figure 4-7
Set terminal emulation in properties setting window
Booting the Switch
Checking before Power-On
Before powering on the switch, verify that:
z
The power cable and grounding cable are properly connected.
z
The power supply voltage is consistent with that required by the switch.
z
The console cable is properly connected; the terminal (which can be a PC) used for configuration
has been started; and the configuration parameters have been set.
Powering On the Switch
The S5810 series have the same Boot ROM display style. This document uses the Boot ROM display of
S5810-50S as an example:
Starting......
************************************************************************
* *
* H3C S5810-50S BOOTROM, Version 103 *
* *
************************************************************************
Copyright (c) 2004-2008 Hangzhou H3C Technologies Co., Ltd.
Creation Date : Dec 15 2008,14:19:14
CPU Clock Speed : 750MHz