3-6
z
Use the PGND cable provided with the switch to connect the grounding strip in the equipment room.
Otherwise, the switch may not be effectively grounded, which easily causes damage to the switch.
z
If no grounding strip is available, refer to
H3C S5810 Series Ethernet Switches Installation Manual
for detailed grounding methods.
Installing a Power Module
The S5810 series provides two power module slots on its rear panel. Hot swappable power module slot
1 is empty when the switch is shipped, and hot swappable power module 2 is installed with a filler panel.
You can select one or two power modules for your switch as needed. For details about optional power
modules, refer to Pluggable Power Modules on page 1-13.
The installation and removal procedure includes the installation and removal of power modules and
power cords. To prevent damage to the device and personal injury, follow the installation and removal
procedures illustrated in Figure 3-9 and Figure 3-10, respectively.
Figure 3-9
Installation procedure
Install the
power module
Connect the
power cord
Switch on the
power module
Install the
power module
Connect the
power cord
Switch on the
power module
Figure 3-10
Removal procedure
Switch off the
power module
Disconnect the
power cord
Remove the
power module
Switch off the
power module
Disconnect the
power cord
Remove the
power module
Verifying the Installation
Before powering on the switch, check that:
z
There is enough space for heat dissipation around the switch, and the rack or workbench is stable.
z
The ground wire is connected.
z
The selected power module matches that required by the switch.
z
The power cables are properly connected.
z
All the interface cables are cabled indoors. If there is any cable wired outdoors, verify that socket
strip with lightning protection and lightning arresters for network ports have been properly
connected.