1-4
Test parameter
Description
Interval to send jitter test
packets (
jitter-interval
)
Each jitter probe will send multiple UDP test packets at regular intervals (you can
set the interval). The smaller the interval is, the faster the test is. But a too small
interval may somewhat impact your network.
Enable the HWPing client to
send Trap messages
(
send-trap
)
z
An HWPing test will generate a Trap message no matter whether the test
successes or not. You can use the Trap switch to enable or disable the output
of trap messages.
z
You can set the number of consecutive failed HWPing tests before Trap
output. You can also set the number of consecutive failed HWPing probes
before Trap output.
HWPing Configuration
The TCP/UDP/jitter tests need the cooperation of HWPing client and HWPing server. Other types of
tests need to configure HWPing client and corresponding different servers.
You can enable both the HWPing client and HWPing server functions on the switch, that is, the switch
can serve as an HWPing client and server simultaneously.
HWPing Server Configuration
The following table describes the configuration on HWPing server, which is the same for HWPing test
types that need to configure HWPing server.
Follow these steps to perform HWPing server configurations:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the HWPing server
function
hwping-server enable
Required
Disabled by default.
Configure a UDP listening
service
hwping-server udpecho
ip-address port-num
Required for UDP and jitter tests
By default, no UDP listening service is
configured.
Configure a TCP listening
service
hwping-server tcpconnect
ip-address port-num
Required for TCP tests
By default, no TCP listening service is
configured.
Note that:
z
The HWPing server function is needed only for jitter, TCP, and UDP tests.
z
You can configure multiple TCP/UDP listening services on one HWPing server, with each listening
service corresponding to a specific destination IP address and port number.
HWPing Client Configuration
HWPing client configuration
After HWPing client is enabled, you can create multiple test groups for different tests, without the need
to enable HWPing client repeatedly for each test group.
Different types of HWPing tests are somewhat different in parameters and parameter ranges. The
following text describes the configuration on HWPing client for different test types.
1) Configuring ICMP test on HWPing client
Follow these steps to configure ICMP test on HWPing client:
Summary of Contents for S3100 Series
Page 74: ...7 7 Sysname ip http acl 2030...
Page 270: ...1 51 Sysname GigabitEthernet1 0 1 port trunk permit vlan all...
Page 579: ...ii Configuration Example 2 4 QoS Profile Configuration Example 2 4...
Page 713: ...1 22 Total associations 1...
Page 823: ...1 16...
Page 1054: ...i Table of Contents Appendix A Acronyms A 1...