5-33
Slot PowerID State Mode Current(A) Voltage(V) Power(W)
1 0 Normal -- -- -- --
1 1 Absent -- -- -- --
Table5-4 Output description
Field
Description
Slot
Slot number of the power supply.
PowerID
Number of the power supply.
State
Power supply state:
•
Normal
—The power supply is operating correctly.
•
Absent
—The power supply is not in position.
•
Fault
—The power supply has failed.
Mode
Type of the power supply:
•
AC
—AC power supply.
•
DC
—DC power supply.
Current(A)
Output current of the power supply. This field displays two hyphens (
--
) if
it is not supported in the current software version.
Voltage(V)
Output voltage of the power supply. This field displays two hyphens (
--
) if
it is not supported in the current software version.
Power(W)
Output power of the power supply. This field displays two hyphens (
--
) if
it is not supported in the current software version.
Displaying the operational status of fan trays
Use the
display fan
command to display the operational status of fan trays.
<Sysname>display fan
SLOT 1 Fan 0 Status: Normal Speed:6666
SLOT 1 Fan 1 Status: Normal Speed:6666
SLOT 1 Fan 2 Status: Normal Speed:6666
SLOT 1 Fan 3 Status: Normal Speed:6666
SLOT 1 Fan 4 Status: Normal Speed:6666
SLOT 1 Fan 5 Status: Normal Speed:6666
Table5-5 Output description
Field
Description
SLOT 1
Member ID of the device.
Fan 0 to Fan 5
Number of the fan tray.
Status
Fan tray status:
•
Absent
—No fan tray is present.
•
Normal
—The fan tray is operating correctly.
•
Faulty
—The fan tray is faulty.
•
NoSupport
—The fan tray is not supported.
•
FanDirectionFault
—The fan tray airflow direction is inconsistent
with the expected fan tray direction.
Speed
Fan tray speed.
The fan tray adjusts its speed automatically to adapt to the device
temperature. The inflow and outflow temperature sensors monitor the