OPERATION 

Precautions during installation 

1. Confirm your electrical outlet is 110V

2. Make sure to use an individual outlet for the appliance

Caution: 

* If the power cord is damaged, replace it in mediately

* Children should not use the appliance without supervision

* If the water pressure exceeds 60 PSI, use a pressure reducing valve.

Procedure 

for 

Operation 

1. Install pinch valve to  water source  (see  page 1)

(Do not connect pinch valve or adapter to hot water source)

2. Connect  water line by  pushing tube in to inlet on the back of the unit

3. Turn on the water supply

4. Wait at least 5 mintues  and then make sure there  is water in both tanks

5. Plug in the appliance  in to a 110V electrical outlet

6. Turn on both the  Hot and Cold switches, located on the back of

the machine

(Do not turn on the hot water switch before making sure there is

water in the tank)

7. Wait up to 50 minutes for cold water to cool and 20 minutes for

hot water to heat

8. If unit will not be used for a long period of time, drain the unit

using the drain cap located in the back of the unit and unplug it.

Hot Water Indicator Light 

Cold Water Indicator Light 

Hot Water Dispenser 

Cold Water Dispenser 

Cold Water Tap 

Hot Water Tap 

-

H 2 0 - 5 0 0   B O T T L E L E S S   W A T E R  C O O L E R  I N S T A L L A T I O N  & O W N E R S  M A N U A L 

Pure n Natural Systems, Inc. | purennatural.com | 1-800-237-9199

Summary of Contents for H20-500

Page 1: ...iew 3 4 Specifications 5 Water Filter Diagram 6 Cleaning Hot Water Reset 8 Filter Replacement 9 Leak Detector 10 Please read the instructions completely before using this product Intended for water p1 essu1 e between 25 60 psi If water pressure is more than 60 psi please use a water p1 essu1 e regulator H 2 0 5 0 0 B O T T L E L E S S W A T E R C O O L E R I N S T A L L A T I O N O W N E R S M A N...

Page 2: ...lowly as far as possible This will fully open the needle valve and allow the piercing tip to tap into the copper or brass water supply line 8 Turn valve to OFF position 9 Turn on water supply and check for leaks 10 To start the flow of waterwith the saddle valve turn handle on the saddle valve fully counter clockwise DO s and DON T s Install the product half an inch from the wall The power plug sh...

Page 3: ... mintues and then make sure there is water in both tanks 5 Plug in the appliance in to a 110V electrical outlet 6 Turn on both the Hot and Cold switches located on the back of the machine Do not turn on the hot water switch before making sure there is water in the tank 7 Wait up to 50 minutes for cold water to cool and 20 minutes for hot water to heat 8 If unit will not be used for a long period o...

Page 4: ... tested and certified by the NSF It removes chlorine THM s Benzene Pesticides Insecticides and other contaminants that may be present in municipal water supplies Stage 3 The Ultra Filtration Membrane filters water down to 002 microns and is highly effective at removing bacteria organic chemicals and other water borne microorganisms Stage 4 This filter utilizes proprietary carbon block technology t...

Page 5: ...leting the steps on page 3 it is likely the hot water safety feature has been triggered and the hot water heating is disabled To reset the Hot Water please complete the following steps II e Place the lower front panel back on the unit WATER RESET Hot water reset switch a Please disconnect the electricity and make sure all power switches are OFF b Locate the Hot Water Reset Switch by looking at the...

Page 6: ...ich will be full of carbon dust After the cooler fills up again turn on the power to the cold and hot tanks Wait a few minutes to assure there are no leaks and close the front panel QC Fitting Collet Push in to release tubing 1 2 Inch To connect insert the tubing 1 2 inch deep until it s sealed by 0 ring and locked by spider teeth To disconnect remove blue clip pull the tubing while pushing down t...

Reviews: