background image

CLEANING 

1. Turn off all switches located at the 

top rear  of the unit 

2. Close the water intake valve.

3.  Unplug the power cord.

4.

Completely drain water from the unit.

Caution:  Water may be HOT!

5.

Unscrew the back two screws

indicated below, and remove the top

plastic cover.

6.

Under the plastic cover, you'll locate

the cooling tank as illustrated above.

7. Remove the top cover of the cooling

tank,  as illustrated above.

8.Gently yet throughly wipe out the

inside of the cooling tank with a clean

cloth.  Do not use any soap or other

detergent.

9.

Secure the top cover of the cooling

tank,  back in place.

10.

Place the plastic cover back in place,

and screw in the 2 screws.

If the  HOT WATER POWER was turned on 

before completing the steps on page 3,  it is 

likely the hot water safety feature has been 

triggered,  and the hot water heating is disabled. 

To reset the  Hot Water please complete the 
following steps: 

II 

e.)  Place the lower front panel back on the unit 

WATER RESET 

Hot water 

reset switch 

a.) 

Please disconnect the 

electricity, and make sure all 

power switches are OFF 

b.) 

Locate the "Hot Water 

Reset Switch" by looking at 

the back of the unit through 
the cooling grate as 

pictured to the left. 

c.) 

Remove the lower front 

panel as pictured to the left, 

and reach in and up with 

your hand to feel for the 

switch. 

d.) 

Press the Hot Water 

Reset Switch. 

f.) 

Please follow the set-up steps on page 3, and ensure there is water in the hot 

tank before turning the power switches back on. 

H 2 0 - 5 0 0   B O T T L E L E S S   W A T E R  C O O L E R  I N S T A L L A T I O N  & O W N E R S  M A N U A L 

Pure n Natural Systems, Inc. | purennatural.com | 1-800-237-9199

Summary of Contents for H20-500

Page 1: ...iew 3 4 Specifications 5 Water Filter Diagram 6 Cleaning Hot Water Reset 8 Filter Replacement 9 Leak Detector 10 Please read the instructions completely before using this product Intended for water p1 essu1 e between 25 60 psi If water pressure is more than 60 psi please use a water p1 essu1 e regulator H 2 0 5 0 0 B O T T L E L E S S W A T E R C O O L E R I N S T A L L A T I O N O W N E R S M A N...

Page 2: ...lowly as far as possible This will fully open the needle valve and allow the piercing tip to tap into the copper or brass water supply line 8 Turn valve to OFF position 9 Turn on water supply and check for leaks 10 To start the flow of waterwith the saddle valve turn handle on the saddle valve fully counter clockwise DO s and DON T s Install the product half an inch from the wall The power plug sh...

Page 3: ... mintues and then make sure there is water in both tanks 5 Plug in the appliance in to a 110V electrical outlet 6 Turn on both the Hot and Cold switches located on the back of the machine Do not turn on the hot water switch before making sure there is water in the tank 7 Wait up to 50 minutes for cold water to cool and 20 minutes for hot water to heat 8 If unit will not be used for a long period o...

Page 4: ... tested and certified by the NSF It removes chlorine THM s Benzene Pesticides Insecticides and other contaminants that may be present in municipal water supplies Stage 3 The Ultra Filtration Membrane filters water down to 002 microns and is highly effective at removing bacteria organic chemicals and other water borne microorganisms Stage 4 This filter utilizes proprietary carbon block technology t...

Page 5: ...leting the steps on page 3 it is likely the hot water safety feature has been triggered and the hot water heating is disabled To reset the Hot Water please complete the following steps II e Place the lower front panel back on the unit WATER RESET Hot water reset switch a Please disconnect the electricity and make sure all power switches are OFF b Locate the Hot Water Reset Switch by looking at the...

Page 6: ...ich will be full of carbon dust After the cooler fills up again turn on the power to the cold and hot tanks Wait a few minutes to assure there are no leaks and close the front panel QC Fitting Collet Push in to release tubing 1 2 Inch To connect insert the tubing 1 2 inch deep until it s sealed by 0 ring and locked by spider teeth To disconnect remove blue clip pull the tubing while pushing down t...

Reviews: