specifications
Display Enclosure
Enclosure Material ............................................................. ABS
Rating ..................................................................................... NEMA 4X / IP66
Dimensions........................................................................... 6” x 6” x 3.5” / 152mm x 152mm x 90mm (HxWxD)
Mounting Brackets (4) ....................................................... Stainless Steel
Display
Display ................................................................................... LCD
Backlight Colors.................................................................. Red, Green, White
Display Cable with Socket .............................................. 138” (3.5M) long
Sensor
Sensor Housing Material ................................................. Polycarbonate (clear)
Molded Cable with Plug ................................................... 20” (0.5M) long
Display to Sensor Extension Cable (optional)
Pre-formed with Attached Plug and Socket .............. 25 feet (7.62M) long
Power Supply
Power Connection ............................................................. Receptacle style
Power Source ...................................................................... 120-240VAC, 0.5 Amps
Power Output ...................................................................... 12 VDC, 1.0 Amps
Low Voltage Cable Length .............................................. 60” (1.52M)
User Extendable ................................................................. Yes, but polarity sensitive
Auxiliary Relay
Output Contacts ................................................................. Double Pole, Double throw Form C Dry Contacts
Contact Ratings ................................................................... 20A max
Relay Coil .............................................................................. 12VDC (sourced and controlled by the Display)
Analog Output (4-20mA)
Scaled to ............................................................................... 4 mA = zero flow, 20 mA = max flow rate limit of installed FlowVis
Output Format ..................................................................... Voltage sourced from FlowVis Digital Display
Maximum Load .................................................................... 250 ohms
Accuracy
Flow Rate Accuracy ........................................................... >98% for all FlowVis models
Environmental
Operating Temperature .................................................... 32 to 122°F (0 to 50°C)
Storage Temperature ........................................................ -4 to 140°F (-20 to 60°C)