dimensions

For product dimensions, please refer to the images below (Fig 2.2 & 2.3). 

Please note: 

Dimensions are the same for 

FlowVis Digital indoor and outdoor models. 

*

Cable glands supplied; not pictured below; please refer to Fig 1.2 on pg.4.

5.970” / 151.638mm

6.135” / 

155.829mm

3.588” / 

91.1352mm

0 0.510” / 

12.954mm*

0 0.610” / 

15.494mm*

installation

a) 

Check the contents to make sure that they comply with section titled ‘Complete FlowVis and FlowVis Digital   

 

 

Installation’, on page 4 of this document.

b) 

Install the standard FlowVis fl ow meter in accordance with its manual

c) 

Mount the FlowVis-Digital Display enclosure in a location that is a) convenient for viewing, b) close enough to  

 

 

the FlowVis fl ow meter for the sensor cable length (including any extension cables you may have purchased),  

 

 

and c) close enough to a 120V receptacle to allow the power supply to connect.

d) 

Connect the Power Supply low voltage (12VDC), output to the Display

e) 

Connect the Sensor to the display using either the standard-length cables provided or the extension cable (if  

 

 purchased) 

Disclaimer: The sensor-to-display cables MUST NOT be cut or spliced in any way. Doing so will invalidate the    

 

FlowVis Digital product warranty. If these cables are longer than needed, we suggest coiling the excess  

 

 

cable and tying with a zip-tie.

f) 

Plug in the Power Supply and ensure that the Digital Display illuminates and the blue light on the sensor is    

 

 

fl ashing.

g) 

If being used, connect 4-20 mA output to external equipment such as a VFD

h) 

If being used, connect the alarm relays

i) 

Proceed to the Programming Section

How to install a complete FlowVis Digital unit

This section covers two scenarios for installing the FlowVis Digital system:

a) Installation of a FlowVis Digital to a ‘complete’ FlowVis installation.
b) Installation of a FlowVis Digital to a previously installed FlowVis (retrofi t)

Fig 2.2

Fig 2.3

Summary of Contents for FLOWVIS

Page 1: ...RTANT NOTE For the most up to date version of this manual please visit www h2flow net product literature English Rev 1 1 10 2019 www h2flow net Tel 888 635 0296 Toll Free OR 1 419 841 7774 International Operating Manual EN ...

Page 2: ...ts Description 3 Compatibility 3 Safety Information 3 What s included 4 Dimensions 5 Installation 5 Wiring 6 Output 7 Programming 8 Operation 8 Advanced Setup 9 Auxiliary Relay 11 Display Features 13 Troubleshooting 13 Environmental 14 Standards Approvals 14 Specifications 15 Warranty 16 2 ...

Page 3: ...dditional details relating to this can be found on Page 12 of the FlowVis Operating Manual Using the Advanced Setup features FlowVis Digital can be interfaced with other systems such as heaters chemical feeders and UV units so that they will only operate above a user defined flow rate When using this option it will be necessary to include the Auxiliary Interface Unit with your purchase compatibili...

Page 4: ...ended length lid screws Fig 1 8 Optional extension cable if purchased Fig 1 9 For 1 5 2 2 5 FlowVis models New flapper with attached indicator arm with magnet Fig 2 0 For 3 and 4 FlowVis models Complete new lid assembly Fig 2 1 Optional Auxiliary Interface Unit Fig 1 0 FlowVis flow meter with pre installed sensor and cable Fig 1 1 120VAC to 12VDC Power Supply Fig 1 2 NEMA 4X enclosure with pre mou...

Page 5: ...s you may have purchased and c close enough to a 120V receptacle to allow the power supply to connect d Connect the Power Supply low voltage 12VDC output to the Display e Connect the Sensor to the display using either the standard length cables provided or the extension cable if purchased Disclaimer The sensor to display cables MUST NOT be cut or spliced in any way Doing so will invalidate the Flo...

Page 6: ...les you may have purchased and c close enough to a 120V receptacle to allow the power supply to connect e Connect the Power Supply low voltage 12VDC output to the Display f Connect the Sensor to the display using either the standard length cables provided or the extension cable if purchased g Plug in the Power Supply and ensure that the Digital Display illuminates and the blue light on the sensor ...

Page 7: ...www h2flow net Tel 888 635 0296 Toll Free OR 1 419 841 7774 International 7 output 4 20 mA Auxiliary Relay Auxiliary Relay Connections Fig 2 6 Fig 2 7 Fig 2 8 ...

Page 8: ...ON OFF ON FV 8 FV 8 L FV C M DN200 8 and DN200 OFF ON ON OFF FV C 15 FV C M DN40 1 5 and DN40 OFF ON ON ON operation After setting the DIP Switches to reflect the FlowVis model and Pipe Size employed in your application the FlowVis Digital is ready to use No calibration or further settings are required However by default the FlowVis Digital readout will display the flow rate in US GPM and the Turn...

Page 9: ...m net A spare USB 2 0 port for later connection to the Display An internet connection Step 1 Download and install the Advanced Panel Display Configurator Software Launch an internet browser page and go to www h2flow net flowvis digital flow meter and locate the Configurator section either by click on the tab titled Configurator in the page header or by scrolling down the page to this section Click...

Page 10: ... 10 advanced setup cont Step 2 Programming the advanced features of the FlowVis Digital Display Connect the Display to your PC using the Type A to Type B cable that was delivered with your FlowVis Digital Open the FlowVis Configurator Program to display the following screen ...

Page 11: ...to see turbulence in the flow stream this may be caused by other equipment such as heaters filters or even simply other plumbing fittings such as tees or elbows Under such conditions it is advisable to set the sensitivity to its default value of Low meaning that the flow readings and any features related to that reading such as the Turnover Rate or the Visual Alarm are not too erratic in their rea...

Page 12: ...ry Relay comprises two sets of double pol double throw dry contacts Both sets of contacts will operate at the same programmed flow rate as set in Step 5 above Each of the two sets of contacts has a normally open and a normally closed relay The normal state is the condition that the contacts are in before they are activated by the coil is energized by the programming value Please refer to the Auxil...

Page 13: ...ing Troubleshooting Guide As always please feel free to contact us with any questions or concerns Tel 888 635 0296 Graphical display of flow rate Unit of measurement options US GPM LPM m3 h Digital readout of flow rate Pool turnover rate in hours H2flow Controls internal reference only Observation Solution Digital Display not illuminated Check Power Supply is plugged into its receptacle if yes Check ...

Page 14: ... further guidance Turnover rate appears to be inaccurate The turnover rate is calculated by the programmed pool volume divided by the flow rate Perform a manual calculation as follows Pool Volume Flow Rate from FlowVis 60 Turnover rate in hours If this number is different to the value shown on the FlowVis Display reconnect your laptop and check that the pool volume has been accurately entered Exte...

Page 15: ... Socket 25 feet 7 62M long Power Supply Power Connection Receptacle style Power Source 120 240VAC 0 5 Amps Power Output 12 VDC 1 0 Amps Low Voltage Cable Length 60 1 52M User Extendable Yes but polarity sensitive Auxiliary Relay Output Contacts Double Pole Double throw Form C Dry Contacts Contact Ratings 20A max Relay Coil 12VDC sourced and controlled by the Display Analog Output 4 20mA Scaled to ...

Page 16: ...mpts of individuals other than H2flow Controls Inc staff to repair or service the product c damage has been caused by the improper use of the product including but not limited to the installation of a FlowVis unit using a chlorination system as described on page 4 of this manual Charges Under cover of this warranty H2flow Controls Inc will pay the carriage and insurance charges for the shipment of...