21
20
| Mounting
Temperature Switch TS 1000
4. mounTIng
– This device may only be operated in enclosed, dry areas.
– The device is designed for permanent wall mounting. A properly installed
230 V socket must be located in the near vicinity of the temperature switch. The
device may only be installed by a competent person or a qualified electrician.
– If this device is installed to control a load that can cause a danger in the event
of malfunction, additional safety measures are required. Make sure that all
devices are connected according to their instruction manuals. Under certain
circumstances the connection to another device (e.g. protective conductor to
ground) can cause extreme surges.
– Keep the device away from spray- or rainwater, dust and direct sunlight.
– When mounted in industrial facilities, the accident prevention regulations for
electrical systems and equipment of the professional associations must be
followed.
– In schools, training centers, clubs and workshops the operation of modules
must be monitored by responsible, trained personnel.
– If the device needs to be repaired only genuine spare parts may be used! The
use of other components may result in serious personal injury and damage.
– When the mains plug of the device is inserted into a correctly mounted,
230 V, earthed socket (connect without load), the lighting of the seven seg-
ment display signals the operational readiness of the device.
5. leDS anD BuTTonS
leD DISplay
1. LED
heizen
is illuminated: the function “heating” was selected
2. LED
kühlen
is illuminated: the function ”cooling” was selected
3. LED
relais
is illuminated:
the relay is switched on
BuTTonS
Button
p
:
increases the selected value
Button
q
:
decreases the selected value
Button
SeT
:
changes the selectable menu or confirms the value.
6. menu
Pressing the button
SeT
will change the input menu as follows:
menu n1 – SWITch on
E 23
In this menu you can enter a temperature at which a connected device is to be
switched on. The value can be changed with the buttons
pq
. The selection is
confirmed by pressing the button
SeT
and the device will move to the next menu.
menu n2 – SWITch oFF
A 21
In this menu you can enter a temperature at which a connected device is to be
switched off. The value can be changed with the buttons
pq
. The selection is
confirmed by pressing the button
SeT
and the device will move to the next menu.
menu n3 – hIgheST meaSureD TemperaTure
H 23
In this menu you can see the highest measured temperature. The value can be
deleted with the buttons
pq
. The selection is confirmed by pressing the button
SeT
and the device will move to the next menu.
menu n4 – loWeST meaSureD TemperaTure
L 12
In this menu you can see the lowest measured temperature. The value can be
deleted with the buttons
pq
. The selection is confirmed by pressing the button
SeT
and the device will move to the next menu.
If no new temperatures have been measured, the display will show four dashes.
----
The device will automatically leave the input mode if a button has not been
pressed within 10 seconds.