ELECTRO FREEZE Model CS600
8
184596
6 Operator Controls –
continued
This two-position regulating device
(figure 6-3) meters the correct amount
of mix and air into the freezing cylinder.
a. “OPEN” - Always use this position
when dispensing product. (See figure 6-4.
When OPEN you can see clear through the
hole in the top of mix feed tube.)
Important:
If product is dispensed when the
regulator is in the “CLOSED” posi-
tion, a freeze-up will occur and may
damage the freezer.
b. “CLOSED” - Use this position
when the freezer is in the “NIGHT”
mode, and when product will not be
dispensed for a long period of time.
(See figure 6-4. When CLOSED you
cannot see through the hole in the top
of the mix feed tube — the white plastic
insert tube inside will block the hole.)
Figure 6-3
Figure 6-4
6.4 Mix Float
(not shown)
6.5 Mix Feed Tube & Insert
Pin
Location
Pin
Location
Insert-Assy.
Miix Feed
When this float is mounted on the float
stem inside the hopper it automatically
senses the mix level. It activates the “Add
Mix” light