5
MAGYS 263 and MAGYS 261
Application with the wire feeder of the generator
Application with a separated wire feeder type WF
Screw down the gas connection from moto generator
wire feeder on the gas connection
Screw off the pipe of moto generator wire feeder and screw
down bank connection by integrating the pipe in the front
side hole.
For
GENEGYS 263 SF
machine,
the gas connection of the bank is uniquely made on front side.
Gas choice
:
STEEL MORE OR LESS ALLOYED
-
Pure CO2 (not much used),
-
Argon + CO2 (universal gas, often used),
-
Argon + CO2 + O2 (not much used).
STAINLESS STEEL
-
Argon + CO2 (often used),
-
Argon + H + CO2 +N (not much used).
ALUMINIUM
-
Pure argon (often used),
-
Argon + Hé (not much used).
5-3) Connection to earth cable
For an application with a wire in normal polarity, you must connect the adapter earth clamp on the negative terminal and
take care to swivel from a ¼ the adapter.
For an application with a thread « without gas », you have to connect the main clamp to the positive terminal.
5-4) Connection of the torch
All torches are with a euro connection, which can be adapted on GYS machines.
5-5) Setting of rollers
Choose those in function of the wire diameter used and the type of wire (See following board). MAGYS 263 and 261
machines are delivered with rollers double groove 0,8 / 1 for steel.
Rollers double
groove
GYS Reference for MAGYS
263 and 261 and wire feeder
WF 324 and 344 W
0,6 / 0,8
041738
0,8 / 1
042094
0,8 / 1 ALU
042148
0,9 / 1,2 NO GAZ
042124
1 / 1,2
042117
1 / 1,2 ALU
042162
1,2 / 1,6
041752
1,2 / 1,6 ALU
041776
5-6) Setting of wire spool
Open the wire feeder compartment. Remove the swivel from the coil support. Take the coil and put it on the support
with taking care to block with base spin, then screw down again the swivel. For an application with a 5Kg coil (or
d=200), put the adapter between the support and the coil. For an application in steel wire place in position the capillary
tube (for an application in aluminium see the paragraph VI).