GYS MAGYS 261 Instruction Manual Download Page 4

 

4

 
MAGYS 263 et 261 : Foreside (Lower part) 

 

Generator wire 
feeder.

 

Commutator of the wire feeder. 
      Position I: generator wire feeder (origin). 
      Position II: separated wire feeder WF 212, 324 or 344 W (in option). 

Gas connection

: allow 

to feed in gas either the 
generator wire feeder or 
a separated wire feeder 
type WF. The 
connection is situated 
near the motor. 

Commutator of 
selection from the 
output voltage. 
Commutator 10 
positions for 
MAGYS 263 and 
commutator 6 
positions for 
MAGYS 261.

 

Operating connector for 
an application with a 
separated wire feeder 
type WF. 

Positive terminal for an 
application with a 
separated wire feeder 
type WF. 

 

 

Negative terminal.  
Allow to connect 
either the main 
clamp or the cable of 
polarity choice of 
the generator wire 
feeder. 

Cable for the polarity choice of the generator wire feeder. In application with gas, put the cable on the left terminal (+).  
For an application without gas, put it on the negative. 
The remaining terminal serve to connect the main clamp.

 

 

GENEGYS 263 SF: Foreside (Lower part) 

 

Operating connector for 
an application with 
separated wire feeder 
type WF.

 

Commutator of 
selection from the 
output voltage. 

 

Negative Terminal 

 

For an application 
with gas, connect the 
main clamp on the 
terminal. 

 

For an application 
without gas, connect 
the wire feeder bank 
type WF on the 
terminal. 
 

Positive terminal 
 
For an application with 
gas, connect the wire 
feeder bank type WF on 
the terminal. 
 
For an application 
without gas, connect the 
main clamp on the 
terminal.

 

 

 

Gas connection of the 
bank

 

 

VI / COMMISSIONING 

 

 

5-2) Connection to gas bottle and gas choice 

 

Screw down the regulator on gas bottle. This one is connected to MAGYS and GENEGYS by a pipe whose terminal end 
is fixated on the electronic valve behind the machine. You must use clamps to avoid escape of gas. 

Summary of Contents for MAGYS 261

Page 1: ...1 INSTRUCTION MANUAL FOR SEMI AUTOMATICAL WELDING MACHINES MAGYS 261 MAGYS 263 GENEGYS 263 SF GYS Mise à jour 25 02 04 Réf 72189 ...

Page 2: ...eventual flashes of the electrical arc with protection clothes like leather gloves welding aprons safety shoes welding helmets or glasses for filtering radiations and projections As well during operations of rubbing and hammering the operator must protect his eyes 2 All the protection board must be in good condition and maintained in place Never look at an arc of welding without any protection of ...

Page 3: ...1 Protection of the line MAGYS 261 Circuit breaker 40A curve D or fuse 40A type aM IV DESCRIPTION OF THE MACHINE MAGYS 261 MAGYS 263and GENEGYS 263 SF Foreside Higher part Potentiometer of instructions wire speed except on GENEGYS 263 SF Commutator On Off Thermal fault indicator it is switch on when the machine is in fault Potentiometer of repose time adjustment when you use spot mode Potentiomete...

Page 4: ...erator wire feeder In application with gas put the cable on the left terminal For an application without gas put it on the negative The remaining terminal serve to connect the main clamp GENEGYS 263 SF Foreside Lower part Operating connector for an application with separated wire feeder type WF Commutator of selection from the output voltage Negative Terminal For an application with gas connect th...

Page 5: ...For an application with a thread without gas you have to connect the main clamp to the positive terminal 5 4 Connection of the torch All torches are with a euro connection which can be adapted on GYS machines 5 5 Setting of rollers Choose those in function of the wire diameter used and the type of wire See following board MAGYS 263 and 261 machines are delivered with rollers double groove 0 8 1 fo...

Page 6: ... the following Don t use the brass capillary tube in the euro adapter but use the Teflon envelope which must come until the moto wire feeder roller In ALUMINIUM use a contact tube of a diameter immediately superior to the section of the wire used Use ALU rollers identical with wire diameter VII OPTION FOR MAGYS 263 et 261 MAGYS 263 and 261 machines are evolutives terminals For origin machine we ca...

Page 7: ...of all projections Use a spray of anti pearl aerosol We advice you to clean the covering situated in the torch by blowing it with compressed air Gas pipe Control cable Power cable To use a wire feeder WF tip the commutator on the position II wire feeder WF Don t forget to transpose the gas connection situated behind the front panel ...

Reviews: