7/33 

F

OR YOUR SAFETY

 

This manual contains important safety and operating instructions. Read this manual carefully before 

using the charger for the first time and keep it in a safe place for future reference.

 

 

P

RODUCT FEATURE

 

 

GYSTECH 7000 is designed for charging a variety of SLA (Sealed Lead Acid) batteries, widely used in 

cars and several other vehicles. The batteries may be of various types i.e. WET/Flooded (Liquid 

Electrolyte), GEL (Gelatin type Electrolyte, absorbed into the plates), AGM (Absorbed Glass Mat) 

batteries. Gystech :  

- charges 12V batteries (6 cells of 2V) from 14 Ah to 130 Ah, or provides maintenance charge for 

12V batteries from 14 to 230 Ah.  

- charges 24V batteries (12 cells of 2V) from 14 Ah to 60 Ah, or provides maintenance charge for 

24V batteries from 14 to 120 Ah. 

It automatically detects the nominal voltage of the battery connected (12/24) (> 7.8 V). 

 

S

AFETY INFORMATION

 

 

-

 

Do not use it for any other purposes 

-

 

Do not attempt to charge non rechargeable batteries 

-

 

Respect the rating of the fuse, which is indicated on the charger. 

-

 

Do not cover the charger while charging. 

-

 

The charger must be placed in such a way that the socket is accessible. 

-

 

Follow fuse size/type indicated on the charger. 

-

 

If the power supply cable is damaged it must be replaced by the manufacturer, its after-sales 

department or by a qualified person in order to avoid danger. 

-

 

Before the charge, read the instructions. Disconnect the power supply before plugging or un

-

plugging connexions on the battery. Warning :  Explosive gas, avoid flames and sparks. Insure 

a sufficient aeration while charging. 

-

 

Charging should be carried out in a well-ventilated, weather protected facility. 

-

 

Separate collection required. Do not throw in a domestic dustbin.  

-

 

This device can be used by children older than 8 and people with reduced physical, sensory or 
mental capacities or without any experience, if they are properly supervised or if instructions to 
use the device safely has been given and if the risks incurred have been understood. Children 
must not play with the device. Cleaning and maintenance by the user must not be done by 
children with no supervision. 

 

C

ONNECTIONS

 

 

 Charging of a permanently installed battery in a vehicle  

a- Before connecting or disconnecting the battery leads, the power cord should be removed from 

the mains. 

b- Check polarity of battery posts. A positive (“+”) battery post usually has a larger diameter than 

a negative one.  

c- Identify the pole of battery which is connected to the chassis (earth). Normally the negative 

terminal is connected to the chassis. 

d- Charging of negative earthed battery :  

- Make sure the black wire (“-” pole connection) has no contact with the fuel line or the battery. 

- Connect the red wire(“+”) to the positive (“+”) pole of the battery and the black wire (“-“) to 

the vehicle chassis. 

e- Charging of positive earthed battery : 

- Make sure the red wire (“+” pole connection) has no contact with the fuel line or the battery. 

- Connect the black wire(“-”) to the negative (“-”) pole of the battery and the red wire (“+“) to 

the vehicle chassis 

 

 Charging of a battery not connected to a vehicle 

130.ua — all for cars!

130.ua

Summary of Contents for GYSTECH 7000

Page 1: ...ccessories SECURITY SYSTEMS Car alarms Bike alarms Mechanical blockers Immobilizers Sensors Accessories OPTIC AND LIGHT Xenon Bixenon Lamps LED Stroboscopes Optic and Headlights Washers Light rain sensors Accessories PARKTRONICS AND MIRRORS Rear parktronics Front parktronics Combined parktronics Rear view mirrors Accessories HEATING AND COOLING Seat heaters Mirrors heaters Screen wipers heaters En...

Page 2: ...C30 V4 1 01 12 2016 GYSTECH 7000 EN 7 11 31 34 130 ua all for cars 1 3 0 u a ...

Page 3: ...g or un plugging connexions on the battery Warning Explosive gas avoid flames and sparks Insure a sufficient aeration while charging Charging should be carried out in a well ventilated weather protected facility Separate collection required Do not throw in a domestic dustbin This device can be used by children older than 8 and people with reduced physical sensory or mental capacities or without an...

Page 4: ...r from supply mains then from the battery connection SUGGESTED MODES AND SELECTION Gystech 7000 provides 5 modes 2 charging modes and 3 specific modes To select your charging mode please refer to the following table and explanations page 4 and 5 charging modes and specific modes MODES LED BATTERY USE BATTERY VOLTAGE SIZE EMERGENCY i e alarm IN CYCLE charging discharging i e sweeper AUTOMOBILE batt...

Page 5: ...nsity of 3 5A 10 The charging process goes on by different stapes until to reach a voltage of 29 4V 0 25V A maintenance current is then delivered to maintain the battery fully charged up Charging process and indicators Once connected to the battery and at the beginning of the charging process Gystech 7000 will automatically checks the voltage of the battery The different charging stapes are descri...

Page 6: ...parck system avoids any spark while connecting the charger to the battery inactive system with the supply mode The charger protects itself charging interruption indicator switched on if the battery voltage is 4 5V 0 5V for a 12V battery or 16V 0 5V for a 24V battery Gystech 7000 charger is protected by a thermal sensor During the charging process if the charger becomes too hot or due to extreme am...

Page 7: ... 33 Recovery mode The recover indicator blinks but the charge evolution indicators haven t changed for several hours Damaged battery Cannot be recovered needs to be replaced 130 ua all for cars 1 3 0 u a ...

Page 8: ...ceso Aan het laden 4 Charge terminée Fully charged Vollladung erreicht Carga efectuada Einde laden 5 Mode Modus Modo Modus 24V 0 C Mode Modus Modo Modus 24V 0 C Mode Modus Modo Modus 12V 0 C Mode Modus Modo Modus 12V 0 C Mode Modus Modo Modus Supply 5A 7 8 9 10 6 13 6V Max 11 Recover 12 Trou de fixation Mounting holes Befestigungslaschen Agujero de fijación Bevestiging gat Câble secteur avec prise...

Reviews: