GYS GYSMI 151 LC Manual Download Page 9

 

9/20 

MAINTENANCE 

 

 

Refer all servicing only to qualified individual. 

 

Disconnect  the power  supply  and wait  until  the  fan  has  stopped before  working  on  the  unit. Inside  the 
device, voltage and current are dangerous. 

 

Regularly  remove  the  steel  cover  and  blow  off  the  dust  with  compressed  air.  Check  the  electrical 
connections (with an insulated tool) by a qualified individual. 

 

Regularly inspect the power cable. If it suffers damaged, it must be replaced by the manufacturer, its after 
sales service or a similarly qualified technician to avoid any danger. 

 
ADVICE  

 

Respect welding polarities and currents indicated on the electrode packaging 

 

Remove the electrode from the electrode holder when you do not use it. 

 

Leave the inlets free to allow in/out air circulation. 

 

SECURITY 

Arc welding can be dangerous and result in serious injury or death. Protect yourself and protect 
others. 
Respect the following warnings: 

 

Arc rays 

Protect yourself with a welding helmet equipped with filters in compliance with EN 169 or 
EN 379.

 

Rain, steam, 
humidity 

Put the appliance in a clean environment (degree of pollution ≤ 3), on an even plataform and 
at least at one meter from the parts to be welded. Do not use it in rain or snow.

 

Electric shocks 

This device must be used on a single phase power outlet with 3-wire with grounded neutral. 
Do not touch live parts. Check that the supply system is suitable for the device.

 

Handling 

Do not carry the device over people or fragile items.

 

Burns 

Wear suitable protective clothing. 

Use fire-proof gloves and apron. 

Protect others by installing a non flammable protection wall, or prevent others accidentally 
viewing the arc and to keep a safe distance from the welding area. 

Fire risks 

Remove all flammable products from the working area. Do not work near flammable gas.

 

Smokes 

Do not inhale gas or welding fumes. If indoors ventilate the area well and/or use local 
extraction ventilation equipment to remove fumes and gases.

 

Extra 
precautions 

Any welding operation:  

- in environments with increased risk of electric shock, 

- in confined spaces, 

- in the presence of flammable or explosive materials, must be evaluated in advance by an 
“Expert supervisor” and must always be carried out in the presence of other people trained to 
intervene in case of emergency. 

Technical protection measures MUST BE taken as described in the TECHNICAL 
SPECIFICATION "IEC 62081".  

Welding in raised positions is forbidden unless safety platforms are used.

 

 

 

 

 

Persons with a pacemaker have to consult a doctor before using these machines 

Do not use the unit to thaw pipes /tubing. 

In TIG welding, manipulate the gas bottle carefully. There are risks if the bottle or the bottle 

valve are damaged. 

 

Summary of Contents for GYSMI 151 LC

Page 1: ...ARCHE 3 THERMAL PROTECTION DUTY CYCLE 8 ENTRETIEN 4 MAINTENANCE 9 NOS CONSEILS 4 ADVICE 9 S CURIT 4 SECURITY 9 RECOMMANDATION POUR R DUIRE LES MISSIONS LECTRO MAGN TIQUES 5 RECOMMENDATION TO REDUCE EL...

Page 2: ...de perturbations conduites aussi bien que rayonn es Ce mat riel ne respecte pas la CEI 61000 3 12 Avant de le connecter au syst me public d alimentation basse tension il est de la responsabilit de l...

Page 3: ...pi ce souder 8 En fin de soudure soulever la torche d un geste rapide ne couper le gaz qu apr s refroidissement de l lectrode Combinaisons conseill es affutage lectrode Courant A Electrode mm fil m ta...

Page 4: ...ls avec neutre reli la terre Ne pas toucher les pi ces sous tension V rifier que le r seau d alimentation est adapt au poste Chutes Ne pas faire transiter le poste au dessus de personnes ou d objets B...

Page 5: ...demander de prendre des pr cautions suppl mentaires h le temps de la journ e au cours de laquelle l appareil devra fonctionner i la surface de la zone prendre en consid ration autour de l appareil d...

Page 6: ...trode en tungst ne correctement pr par e Arc instable D bit de gaz trop important R duire le d bit de gaz Zone de soudage Prot ger la zone de soudage contre les courants d air L lectrode en tungst ne...

Page 7: ...t comply with the standard CEI 61000 3 12 Before connecting the unit to the public low voltage network the user must be sure that he is permitted to connect them Do not use the machine in an area cont...

Page 8: ...y when the electrode has cooled Recommended combinations Electrode grinding Current A Electrode mm wire filler metal Nozzle mm Flow rate Argon L mn 0 5 5 10 130 1 6 9 8 6 7 4 7 130 190 2 4 11 7 8 To o...

Page 9: ...be used on a single phase power outlet with 3 wire with grounded neutral Do not touch live parts Check that the supply system is suitable for the device Handling Do not carry the device over people or...

Page 10: ...be considered will depend on the structure of the building and any other process in the area The surrounding area may extend beyond the boundaries of the building Recommendation to reduce electro magn...

Page 11: ...r electrical network Your unit does not weld correctly Polarity error Check the polarity advised on the electrode packaging MMA TIG When starting up the display indicates The voltage is not included i...

Page 12: ...atibilidad electromagnetica a causa de perturbaciones conducidas tan bien como radiadas Esto equipo no respeta la CEI 61000 3 12 Antes de conectarle al sistema publico de alimentacion de baja tension...

Page 13: ...ue soldar 8 Al final de la soldadura la antorcha con gesto r pido cerrar el gas nicamente tras enfriamiento del electrodo Combinaciones aconsejadas afilar los electrodos Corriente A Electrodo mm hilo...

Page 14: ...do de poluci n 3 de plano y no m s alto que 1 metro de la parte a soldar No utilizar bajo lluvia o nieve Choques el ctricos Este aparato fue concebido para funcionar solamente con una alimentaci n mon...

Page 15: ...quipo El usuario tendr que asegurarse que los dem s equipos del lugar son compatibles entre ellos Esto podr requerir precauciones suplementarias h El tiempo del d a durante el cual se tendr que hacer...

Page 16: ...Error de polaridad Comprobar la polaridad aconsejada sobre el embalaje del electrodo Durante la puesta en marcha del aparato el indicador indica La tensi n de alimentaci n no est entre 110V 15 Compro...

Page 17: ...ltage 2006 95 CE of 12 12 2006 and the instructions of CEM 2004 108 CE of the 15 12 2004 This conformity respects the standards EN60974 1 of 2005 EN 50445 de 2008 EN60974 10 of 2007 CE marking was add...

Page 18: ...Connectors Conectores 51469 2 Clavier Display Teclado 51911 3 Carte lectronique Electronic card Tarjeta electr nica 97109C 4 Pieds Feets Pies 71138 5 Ventillateur Fan ventilador 51021 6 Grille Protect...

Page 19: ...0 C with a delay of 20 s between each electrode Cantidad de electrodos normalizados soldables en 1 hora a 20 C incluyendo una parada de 20 seg entre cada electrodo Nombre d lectrodes normalis es souda...

Page 20: ...dor modo soldadura con electrodo recubierto MMA Indicador modo soldadura con electrodo refractario TIG 4 5 6 S lecteur valeur ou Bouton s lection validation Voyant de protection thermique Select butto...

Reviews: