12
EASYMIG 85
EN
TRANSPORT AND TRANSIT OF THE WELDING MACHINE
This welding power source comes equipped with a top strap so that it can be carried by hand. Be careful not to
underestimate its weight. The strap is not intended to be used to suspend or hang the device.
Do not use the cables or torch to move the welding power source. It should be moved in an upright position. Do not carry
or transport the power source overhead of people or objects. It is advisable to remove the wire-feed spool before lifting or
transporting the welding power source.
EQUIPMENT INSTALLATION
• Put the machine on the floor (maximum incline of 10°).
• Ensure the work area has sufficient ventillation for welding, and that there is easy access to the control panel.
• The machine must not be used in an area with conductive metal dusts.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
• The machine protection level is IP21, which means :
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against vertically falling drops.
The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not incur any responsability regarding damages to both objects and persons that result
from an incorrect and/or dangerous use of the machine.
Stray welding currents/voltages may destroy earth conductors, damage electrical equipment or cause components
to warm up which may cause a fire.
- All welding connections must be firmly secured, check regularly !
- Check that the metal piece fixation is strong and without any electrical problems !
- Attach or hang all the electrically conductive elements,such as the trolley in order to insulate them.
- Do not place any electrical equipment such as drills on top of the welding machine without insulating them !
- Always place welding torches or electrodes holders on an insulated surface when they’re not in use !
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
• Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance
work. DANGER High Voltage and Currents inside the machine.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical
connections checked by a qualified person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced
by the manufacturer, its after sales service or an equally qualified person.
• Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION - USING THE PRODUCT
Only experienced personnel, authorised by the manufacturer, may carry out the machine’s set-up. During set-up, ensure that the
power source is unplugged from the mains. It is recommended to use the welding cables supplied with the unit in order to obtain
the optimum product settings.
DESCRIPTION
Thank you for choosing GYS! In order to get the most out of your machine, please read the following carefully:
The EASYMIG 85 is a semi-automatic, gasless, welding machine for use with flux-cored wires. It is manually adjustable and aided
by the calibration table present on the product. This machine is recommended for welding steel.
Summary of Contents for EASYMIG 85
Page 30: ...30 EASYMIG 85 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Page 31: ...31 EASYMIG 85 RU 11 2 A CEI 61000 3 12 CEI 61000 3 11 EMF EMF...
Page 32: ...32 EASYMIG 85 RU b c d e f g h 10 CISPR 11 a b c d e...
Page 33: ...33 EASYMIG 85 RU f 10 IP21 12 5 1 2...
Page 36: ...36 EASYMIG 85 RU 041806 230 NO GAS 2...
Page 65: ...65 EASYMIG 85 I 4 2 1 3 5 7 6 C B II A 3 2 1 E D 4...
Page 71: ...71...
Page 72: ...GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...