16
EASYMIG 110-130-140-150
EN
GAS COUPLING
- Connect a pressure regulator to the gas bottle. Connect the welding machine (fig. F) using the pipes supplied, and place the two
clamps to avoid leakages.
- Set the gas flow by adjusting the dial located on the pressure regulator.
NB : to help facilitate the adjustment of the gas flow, operate the drive rollers by pressing the trigger of the torch (ensure that the
drive roller is completely loose so the wire is not fed through).
This procedure does not apply to «Gasless» welding mode.
RECOMMENDED COMBINATIONS
(mm)
Current (A)
Ø Wire (mm)
Ø Nozzle (mm)
Flow rate L/min
MIG
0.8-2
20-100
0.8
12
10-12
2-4
100-200
1.0
12-15
12-15
MAG
0.6-1.5
15-80
0.6
12
8-10
1.5-3
80-150
0.8
12-15
10-12
RISK OF INJURY DUE TO MOVING PARTS
The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries! Take extra
care.
• Do not lay a hand to swivel or moving components or parts to the drive!
• Ensure that the housing covers or protective covers remain closed during operation!
• Do not wear gloves when threading the filler wire and changing the filler wire spool.
ADVICE & THERMAL PROTECTION
This device is equipped with a ventilator regulated by the inside temperature. When the machine’s thermal protection is activated, it
will not deliver any current. Orange light (Fig-V-2) will turn on until the temperature of the machine has returned to normal.
• Do not block/cover the ventillation holes, ensure free flow of air.
• Whilst in thermal protection mode leave the machine plugged into the mains after welding to allow it to cool.
General observations :
• Always respect the basic rules of welding.
• Always work in an adequately ventillated area.
• Do not work on a damp surface.
TROUBLESHOOTING
SYMPTOMS
POSSIBLE CAUSES
REMEDIES
The welding wire speed is not
constant.
Debris is blocking up the opening.
Clean out the contact batch or change it and replace
the anti-adherence product.
Ref.041806.
The wire skids in the rollers.
• Control the roller pressure or replace it.
• Wire diameter non-compatible with roller
• Covering wire guide in the torch non-compatible.
The wire-feeder motor doesn’t
operate.
Reel or roller brake too tight.
Release the brake and rollers.
Electrical supply problem.
Check that the power switch is in the "On" position.
Bad wire feeding.
Covering wire guide dirty or damaged.
Clean or replace
The drive roller is too loose
Tighten the drive roller knob
Reel brake too tight
Release the brake
No welding current
Bad connection to the main supply.
Check the mains connection and look if the plug is fed
by 230 V (1PH) power socket.
Bad earth connection.
Check the earth cable (connection and clamp condi-
tion).
Torch trigger inoperative.
Check the torch trigger / replace torch
The wire jams (after the rollers)
Guide wire sheath crushed.
Check the sheath and torch body.
Wire jammed in the torch
Clean or replace.
No capillary tube.
Check the presence of capillary tube.
Wire speed too fast
Reduce the wire speed
Summary of Contents for EASYMIG 110
Page 35: ...35 EASYMIG 110 130 140 150 RU 11 2 A CEI 61000 3 12 CEI 61000 3 11...
Page 36: ...36 EASYMIG 110 130 140 150 RU EMF EMF b c d e f g h 10 CISPR 11 a...
Page 37: ...37 EASYMIG 110 130 140 150 RU b c d e f 10 IP21 12 5 1...
Page 41: ...41 EASYMIG 110 130 140 150 RU 2...
Page 77: ...77 EASYMIG 110 130 140 150 V 2 4 3 1...
Page 81: ...81 EASYMIG 110 130 140 150 EASYMIG 130...
Page 82: ...82 EASYMIG 110 130 140 150 EASYMIG 140...
Page 83: ...83 EASYMIG 110 130 140 150 EASYMIG 150...
Page 88: ...GYS SAS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex France...