TROUBLESHOOTING
CAUSES
SOLUTIONS
1
The machine beeps,
+
All the selected indicators lash (voltage/
capacity/charging curve).
+
the display lashes :
The Batium has detected a polarity
reversal to the clamps.
Connect the red clamp to the positive
terminal (+) and the black clamp
to the negative terminal (-) of the
battery.
2
The « SOS Recovery » indicator lashes.
The battery has suffered a deep
discharge over a long period.
Activate the « SOS Recovery » mode, (see
p7)
3
By positionning the interruptor to « ON »,
no indicator switches on.
The charger has detected an abnormal
mains power supply voltage.
Wait 10 seconds. If nothing is dis-
played, try another power socket.
4
During the charge,
The display shows :
The machine is overheating.
Use the charger in a well ventilated
area.
5
The display’s leds rotate
The indicators « battery voltage », «
capacity » and « charging curve » are
switched on.
Deeply discharged battery (voltage
below 2 V).
Start a forced charge, « see forced
charged section ».
The Batium does not detect the bat
-
tery. The clamps are not connected
properly.
Make sure that the clamps are properly
connected. Carry out the connection
again.
6
The display lashes
+
the voltage indicator stays on
+
a new voltage indicator lashes.
The Batium detects a voltage error and
suggests another selection (voltage
indicator lashes).
Select the proper voltage at least 10
seconds after the irst press.
If the voltage is not rectiied within a
minute, the Batium starts the charge
automatically using the suggested
voltage (lashing indicator).
7
The displays shows
and lashes.
The battery is in short-circuit or
damaged.
Change the battery.
A power consumer has been left on
accidentaly during the charge. (e.g :
lights).
Switch off the power consumer and
continue/restart the charge.
The charger is used as a power supply
to compensate for the use of power
consumers that are dragging the batte
-
ry’s energy.
Charger behaves normally but incor
-
rect use. The indicator that signals the
end of the charge cannot switch on.
The charging speed is not adapted to
the battery.
Select a higher charging speed .If
you’re already set at 25 A, use a more
powerful charger.
8
The display shows
for more than 1 min
and the indicator
is on.
CHE = check
The voltage is still too low to start a
normal charge.
The charger will attempt to recover the
battery for 30 minutes max, then will
resume a normal charge.
If the battery cannot be recovered, the
Barium will stop the charge and display
« OUT ».
Check all electrical consumers are
switched off on the vehicle (e.g.
lights, interior light).
Check that the selected voltage
matches the battery voltage. If that’s
not the case, disconnect the charger’s
clamps and reconigure the charger.
The battery voltage is abnormally low,
the battery is damaged or in short-
circuit.