13
BATIUM 25/24
EN
Translation of the original instructions
GENERAL DESCRIPTION
The 25/24 was designed for two purposes :
The IUoU charging curve can charge liquid or gel electrolyte batteries (lead, lead Calcium, lead Calcium-silver, AGM...) from 35 Ah to 350 Ah
in 6, 12 or 24 V.
The IUIo charging curve can charge traction batteries (e.g. for forklifts, loor sweepers...), from 35 Ah to 180 Ah in 6, 12 or 24 V.
CONNECTIONS AND GENERAL OPERATIONS
Ensure that the correct sequences are followed.
Precaution: Check the electrolyte level for open batteries. Fill it up if necessary, before starting the charge.
1. Connect the clamps : Red clamp to the battery’s (+) and black clamp to the battery’s (-).
Speciic to the IUIo mode
Connect the charger :
- directly to the battery, using the charger’s standard clamps.
- or the device’s speciic connector, by replacing the clamps with a dedicated connector while observing the correct polarity
and current .
2. Connect the charger to the 230 V mains.
3. Turn the switch to «ON». The display’s leds rotate.
IUoU
IUIo
4. Choose the charging curve ( button 5 p.5):
- IUoU for automotive batteries,
- IUIo for traction batteries. To choose the IUIo mode, press 5 seconds.
5. Select the battery voltage (6, 12, 24 V) according to the recommendations features on the battery or according to the
battery coupling (series or parallel, see p.5).
6. Choose the charging speed depending on the battery capacity (Ah) ( 3 p.5).
IUoU
35
95
200
95 Ah
225 Ah
350 Ah
15 A max
7 A max
25 A max
IUIo
45
90
120
8h
90 Ah
150 Ah
180 Ah
14h
15 A max
7 A max
25 A max
7. Before starting the charge, the Batium performs the fol
-
lowing operations :
While the leds rotate
(
4
p.5), it is still possible to
change the settings.
a- battery analysis : battery state/voltage… The Batium
signals an anomaly (see table p7).
The message
(check ) appears on the display. The
settings cannot be modiied.
b- It recovers the battery when the voltage is too low.
The message
remains in the display, as long as the
Batium recovers the battery.
8. The Batium starts the charge and indicates the battery state of charge as well as the charging current in amperes (
1
p.5)
Indicator on
Display
Step 1 :
Electrical current display.
Depending on the battery, the current can rise or fall.
«SOS Recovery» mode
Analysis, start of the
desulfation and recovery,
battery voltage
IUoU & IUIo mode
Main charge.
Charging current.
Step 2 :
Equalisation (duration : 2h).
Step 3 :
Charge is inished
Floating charge.
End of charge (IUIo).
The battery cannot
be recovered.