12
Operating manual
GYSFLASH S 1.12 PL
Translation of the original
instructions
If the motorcycle is equipped with a 12 V socket, the Gysflash S 1.12 PL is able to charge the battery via this socket
with the CAN-BUS system, without having to switch on the instrument panel. In this setup, connect the cigratte lighter
adapter (ref. 029439) on the charger and the 12 V socket of the motorcycle and then follow the «Start-up» procedure
detailed above. In certain cases, it is possible that the charge will only start 2 minutes after performing the connections.
• Protections :
The Gysflash S 1.12 PL has a set of devices to protect it against short circuits and polarity reversal. It has an an
-
ti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has double insulation
and is safe to use with the battery in situ as it will protect the vehicle’s on-board electronics.
The Gysflash S 1.12 PL is equipped with an integrated temperature sensor that allows it to adapt its charging current according to the ambient tem
-
perature in order to avoid any overheating of the internal electronics.
TROUBLESHOOTING, CAUSES, SOLUTIONS
Troubleshooting
Causes
Solutions
1 The indicator
blinks rapidly.
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
• Check that the clamps are correctly connected
• Check that it is a 12 V battery.
2 The indicator
blinks slowly.
Battery out of order or very low voltage. Change the battery.
3 The indicator
is on.
Failure during charging, battery not
recoverable.
Change the battery and press
to restart a
charge.
4 Indicator
stays on even after pressing
button.
Thermal protection
Ambient temperature is too high (>60°C), cool the
room and let the charger cool down.
5 Indicator
flashes.
Charger in sleep mode.
Press button
or connect a battery to the char-
ger to exit sleep mode.
6 Indicator stays on.
Charge interrupted by pressing
.
Press
again to restart the charge.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported