1.
Press the button (10), the pump stops and the LED (9) switches on.
2.
Place the lance on its supports and put the cable on the ground (to prevent loss of cooling liquid).
3.
If the Powerduction is equipped with a complete inductor, unscrew it with the key of 27 (sup-
plied with the product). If it is equipped with a simple inductor, unscrew it manually and then
unscrew the adapter if necessary.
The Powerduction 37LG is equipped with a fixed connection S, it cannot be unscrewed.
4.
Depending on the choice of the new inductor: screw on a complete inductor using the wrench
supplied or screw on the appropriate adapter (7 N.m max) and then screw on the new inductor
manually.
5.
Press the button again (10).
The pump activates. For 5 seconds, the LEDs display a wait pattern.
If the flow is correct, the machine emits a double «BEEP» and the product is ready to operate.
Otherwise a fault is displayed (refer to the fault code table).
Inductors and Adapters
The Powerduction 37LG is equipped with a fixed connection S and
is supplied
as standard with the S90 inductor.
The Powerduction 39LG and 50LG
are delivered with the complete C20/B1 inductor.
The other accessories are optional, they extend the heating possibilities to a wide range of applications.
Complete inductors
Adapters
C20/B1
Ref. 056862
28S
Ref. 064485
28L
Ref. 064492
C180/B1
Ref. 056879
Inductors
S90
Ref. 058927
S70
Ref. 061569
L90
Ref. 059788
C180/B2
Ref. 056886
S180
Ref. 059269
S20/B1
Ref. 064874
L70
Ref. 059771
S180/B1
Ref. 064881
S180/B2
Ref. 064928
L180
Ref. 059795
«PURGE» MODE (50LG)
This mode is only available if the heat is not activated (green switch is off).
1.
Push the button (10), the pump stops and the LED (9) lights up.
2.
Position the torch on its support and place the cable on the floor (to avoid liquid spillage).
3.
Unscrew the accessory using key 27 (supplied with the machine).
4.
Push and hold the heat authorisation button (2) for 3 seconds until it lights up.
5.
Place the torch button above a bucket with a capacity of 10l minimum.
6.
Push the torch button (11). The pump activates until the debit falls under 1l / minute or for 2 minutes. The ma-
chine displays the debit in decilitre per minute.
7.
To interrupt the pump during the cycle, push any button.
8.
To empty the cooling circuit, use a blower to blow air (30PSI) at the end of the torch until you can hear the air
flowing or projections of liquid coming out of the tank.
9.
To empty the tank, use a pump or push the machine forward in order to have it at an angle.
2
Summary of Contents for 055599
Page 7: ...POWERDUCTION 37LG 39LG 50LG 7 2 vis M5x16 41072 2 vis M8x40 42066 ...
Page 8: ...8 POWERDUCTION 37LG 39LG 50LG 39LG 2 vis M8x40 42066 2 vis M5x10 41025 6 vis M6x16 41032 ...
Page 9: ...POWERDUCTION 37LG 39LG 50LG 9 37LG si option chariot if trolley option ...
Page 99: ......
Page 100: ...SAS GYS 1 rue de la Croix des Landes CS 54159 53941 SAINT BERTHEVIN Cedex ...