12
ENERGY STATION
EN
Translation of the original instructions
6
Internal batteries and charging clamps
23 cm
43 cm
53 cm
Before any use, instal both « internal batteries » (not provided) : 12V lead
batteries with liquid or gel electrolyte of a maximum capacity of 120 to 170 Ah
each. Their dimensions must not exceed 45x 53x23 cm, and 100 kg for the total
weight.
To install them:
• Unplug the power supply cable or place the charging switch on « 0 ».
• Fasten the 4 collars supplied on the 4 cables.
• Connect the batteries to the Energy Station respecting the polarities:
-
Red cable to the b
-
Black cable to the battery –
USE: WARNING
In rest position, the charging clamps must ab-
solutely be placed on their support and not on
the handle which could risk electrical arcs and
short circuits resulting in a highly discharge of
the battery.
YES
NO
STARTER MODE
12V Mode
ou
ou
• Unplug the power supply cable or place the charging switch on « 0 ».
• Connect the cables to the battery outputs 1 or 2.
• Connect the clamp to the battery of the vehicle to start respecting the polarities.
• Go to the driver’s seat and turn the ignition key. If your engine does not start, wait 3 minutes
until next attempt. ( 6 sec max)
- If the cooling period between each attempt (3 minutes) is not observed or if the duration of
the attempt is too long (> 6 seconds), the chances of a successful jumpstart are significantly
reduced (risk of power loss).
- Risk of battery acid leaks or damage if the recommended periods are not observed.
- If the vehicle does not start, it may be a problem other than a faulty battery: alternator,
glowplug…
• Charge the batteries after using. (see charger mode)