APPENDIX
97
Environmental Conditions
Operating
temperature range
0 ~ +40
°
C
Storage temperature
range
-10 ~ +70
°
C
Operating humidity
range
20 ~ 80% RH (no condensation)
Storage humidity
range
80% RH or less (no condensation)
LCD Display
4.3 inch, 480 (RGB) x 272
Dimensions (mm)
W
430
430
H
88
88
D
400
560
Weight
24 Kg
38 Kg
Test Function
Number of Memories
10 (0~9 numeric keys)
Step Time Setting Range
0.01 ~ 99.99 S
Operation within Step
Constant, Keep, Linear Sweep
Parameters
Output Range, Frequency,
Waveform (sine wave only)
Interface
Standard
USB Host, LAN
Optional
GPIB (APS-001), RS232/ USB CDC (APS-002)
Product specifications are subject to change without notice.
*1 Maximum output current at working voltage 200Vrms, 400Vrms, 800Vrms
*2 45Hz to 500Hz, 10% or higher of the rated output voltage, the maximum
current or lower.
*3 All of measurement accuracy is at 23±5
°
C.
*4 In the case of 25V to 250V / 50V to 500V / 100V to 1000V sine wave, no load.