40
9.2 GENERAL CLEANING
03
Attention Danger of injury!
For safety reasons you must only carry out servicing and cleaning when the heating
system is switched off and disconnected from the mains, and has cooled down!
Safety notice!
Check the function of the safety valve at least once a year!
You have to make the generalcleaning twice in one year. The
minimum cleaning is anual. For that you have to lead the points 1-
7 for intermediated cleaning:
Lead the following Steps in the numbered order:
8) Open the smokegasbox (7) and pull the cover angel (8) in above
direction. Suct the ash with an ash suction to the ID Fan (10)
between the warmexchangerpipe (9) and the smokegas.
Fire danger through rest ember!
9) Controll the lambdasond (12) to an tight hub, if necaserry built it
out and clean it with an soft brush.
Don´t clean the Lambdasond with highairpressure!
10)
Take off the foto cell (13) and clean it with an soft cloth. Open
the revision lid (14) and check if on the switch surface are any
sediments. If necessary clean it with an chamber cleaner.
11) Activate the programme „grate cleaning“ and let the Tipping
grate deactivated. At opened tipping grate (5) control the
burning chamber, cotroll and if necessary clean it.
Risk of injury from moving parts!
12)
Close the tipping grate again (5) and check if the chamber is
able to close (16).
13)
Remove the restember left and right out of the ashroom (17)
with an poking stick. Then out the ashbox inside and close it.
14)
Mount the rebuilted boilerparts carefully again, and check the
cleaningopenings on tightness.
15)
Attitudes in the Costumermenu:
Took the parameter „ash emptied“ to „YES“ and
confirm with „OK“.
1
1
9
10
11
9
12
13
14
15
16
17
17
7
8